» Articles » PMID: 3977693

Effectiveness of a Pinhole Method for Visual Acuity Screening

Overview
Journal Arch Ophthalmol
Specialty Ophthalmology
Date 1985 Feb 1
PMID 3977693
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Visual acuity screening was performed in the home in an adult population, using a standardized, retroilluminated chart. A pinhole disk was utilized to retest those subjects who initially failed the screening. All subjects failing the screening with the pinholes, and an equal number of age-matched subjects passing the screening (controls), were asked to have a complete ophthalmologic examination, including a protocol refraction in an eye clinic (clinic examination). Without use of the pinhole disk, 14.4% of subjects failed to read a 20/40 line. Use of the pinholes reduced the failure rate to 6.9%. Fifty-seven percent of those failing and 55% of controls had the clinic examination. Determination of best-corrected visual acuity after protocol refraction in the clinic indicated that the false-positive rate (the percentage of subjects who failed the screening but had visual acuity of 20/40 or better on the clinic examination) for the screening was 26%, and the false-negative rate (the percentage of subjects who passed the screening but had visual acuity of worse than 20/40 on the clinic examination) was 1.5%. Use of a pinhole disk is highly effective for visual acuity screening, reducing the false-positive rate by more than half.

Citing Articles

The Rapid Assessment of Avoidable Blindness survey: Review of the methodology and protocol for the seventh version (RAAB7).

McCormick I, Butcher R, Ramke J, Bolster N, Limburg H, Chroston H Wellcome Open Res. 2024; 9:133.

PMID: 38828387 PMC: 11143406. DOI: 10.12688/wellcomeopenres.20907.1.


Validity and Reliability of Vis-Screen Application: A Smartphone-Based Distance Vision Testing for Visual Impairment and Blindness Vision Screening.

Abdul Rahman S, Naing N, Othman A, Mohamad Z, Ibrahim T, Hashim S Medicina (Kaunas). 2023; 59(5).

PMID: 37241144 PMC: 10224196. DOI: 10.3390/medicina59050912.


Results of the Pinhole Test Correlate with Hybrid Contact Lens Visual Acuity in Patients with Visual Impairment due to Corneal Diseases.

Kanclerz P J Ophthalmol. 2022; 2022:4932856.

PMID: 35783341 PMC: 9249474. DOI: 10.1155/2022/4932856.


Accuracy of autorefraction in an adult Indian population.

Kumar R, Moe C, Kumar D, Rackenchath M, A V S, Nagaraj S PLoS One. 2021; 16(5):e0251583.

PMID: 34010350 PMC: 8133404. DOI: 10.1371/journal.pone.0251583.


Effective refractive error coverage: an eye health indicator to measure progress towards universal health coverage.

McCormick I, Mactaggart I, Bastawrous A, Burton M, Ramke J Ophthalmic Physiol Opt. 2019; 40(1):1-5.

PMID: 31879992 PMC: 7004023. DOI: 10.1111/opo.12662.