» Articles » PMID: 39766275

Fast and Sensitive Detection of Anti-SARS-CoV-2 IgG Using SiO@Au@CDs Nanoparticle-Based Lateral Flow Immunoassay Strip Coupled with Miniaturized Fluorimeter

Overview
Journal Biomolecules
Publisher MDPI
Date 2025 Jan 8
PMID 39766275
Authors
Affiliations
Soon will be listed here.
Abstract

The development of a novel strategy for the measurement of SARS-CoV-2 IgG antibodies is of vital significance for diagnosis and effect of vaccination evaluation. In this investigation, an SiO@Au@CDs nanoparticle (NP)-based lateral flow immunoassay (LFIA) strip was fabricated and coupled with a miniaturized fluorimeter. The morphology features and particle sizes of the SiO@Au@CDs NPs were characterized carefully, and the results indicated that the materials possess monodisperse, uniform, and spherical structures. Finally, this system was employed for SARS-CoV-2 IgG antibody test. In this work, the strategy for the SARS-CoV-2 IgG antibody test possesses several merits, such as speed (less than 15 min), high sensitivity (1.2 × 10 mg/mL), broad linearity range (7.4 × 10~7.4 × 10 mg/mL), accurate results, high selectivity, good stability, and low cost. Additionally, future trends in LFAs using quantum dot-based diagnostics are envisioned.

References
1.
Liu A, Cai H, Zeng Y, Chen Y, Yu X, Song J . Nitrogen-doped carbon dots with high selectivity for hydrosulfide sensing and their living cells imaging. Anal Chim Acta. 2022; 1225:340202. DOI: 10.1016/j.aca.2022.340202. View

2.
Hossain F, Shen Q, Balasuriya N, Law J, Logan M, Houghton M . Utilization of a Glucometer Test Strip and Enzymatic Reactions to Quantify Anti-SARS-CoV-2 Spike RBD IgG Antibody and SARS-CoV-2 Virus in Saliva and Serum. Anal Chem. 2023; 95(19):7620-7629. DOI: 10.1021/acs.analchem.3c00481. View

3.
Nam T, Choi M, Jung Y . Ultrahigh-resolution quantum dot patterning for advanced optoelectronic devices. Chem Commun (Camb). 2023; 59(19):2697-2710. DOI: 10.1039/d2cc05874j. View

4.
Naorungroj S, Srisomwat C, Khamcharoen W, Jampasa S, Pasomsub E, Shin K . Sequential Flow Controllable Microfluidic Device for G-Quadruplex DNAzyme-Based Electrochemical Detection of SARS-CoV-2 Using a Pyrrolidinyl Peptide Nucleic Acid. Anal Chem. 2023; 95(34):12794-12801. DOI: 10.1021/acs.analchem.3c01758. View

5.
Mao G, Li Y, Wu G, Ye S, Cao S, Zhao W . Construction of ratiometric Si-Mn:ZnSe nanoparticles for the immunoassay of SARS-CoV-2 spike protein. Sens Actuators B Chem. 2022; 369:132306. PMC: 9250813. DOI: 10.1016/j.snb.2022.132306. View