» Articles » PMID: 39687850

A Novel Approach for Contactless Heart Rate Monitoring from Pet Facial Videos

Overview
Journal Front Vet Sci
Date 2024 Dec 17
PMID 39687850
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Monitoring the heart rate (HR) of pets is challenging when contact with a conscious pet is inconvenient, difficult, injurious, distressing, or dangerous for veterinarians or pet owners. However, few established, simple, and non-invasive techniques for HR measurement in pets exist.

Methods: To address this gap, we propose a novel, contactless approach for HR monitoring in pet dogs and cats, utilizing facial videos and imaging photoplethysmography (iPPG). This method involves recording a video of the pet's face and extracting the iPPG signal from the video data, offering a simple, non-invasive, and stress-free alternative to conventional HR monitoring techniques. We validated the accuracy of the proposed method by comparing it to electrocardiogram (ECG) recordings in a controlled laboratory setting.

Results: Experimental results indicated that the average absolute errors between the reference ECG monitor and iPPG estimates were 2.94 beats per minute (BPM) for dogs and 3.33 BPM for cats under natural light, and 2.94 BPM for dogs and 2.33 BPM for cats under artificial light. These findings confirm the reliability and accuracy of our iPPG-based method for HR measurement in pets.

Discussion: This approach can be applied to resting animals for real-time monitoring of their health and welfare status, which is of significant interest to both veterinarians and families seeking to improve care for their pets.

References
1.
Lowe G, McCane B, Sutherland M, Waas J, Schaefer A, Cox N . Automated Collection and Analysis of Infrared Thermograms for Measuring Eye and Cheek Temperatures in Calves. Animals (Basel). 2020; 10(2). PMC: 7070973. DOI: 10.3390/ani10020292. View

2.
Ueda Y, Slabaugh T, Walker A, Ontiveros E, Sosa P, Reader R . Heart Rate and Heart Rate Variability of Rhesus Macaques () Affected by Left Ventricular Hypertrophy. Front Vet Sci. 2019; 6:1. PMC: 6349711. DOI: 10.3389/fvets.2019.00001. View

3.
Wang W, den Brinker A, Stuijk S, de Haan G . Algorithmic Principles of Remote PPG. IEEE Trans Biomed Eng. 2017; 64(7):1479-1491. DOI: 10.1109/TBME.2016.2609282. View

4.
Liu X, Yang X, Jin J, Li J . Self-adaptive signal separation for non-contact heart rate estimation from facial video in realistic environments. Physiol Meas. 2018; 39(6):06NT01. DOI: 10.1088/1361-6579/aaca83. View

5.
Pongkan W, Jitnapakarn W, Phetnoi W, Punyapornwithaya V, Boonyapakorn C . Obesity-Induced Heart Rate Variability Impairment and Decreased Systolic Function in Obese Male Dogs. Animals (Basel). 2020; 10(8). PMC: 7460129. DOI: 10.3390/ani10081383. View