» Articles » PMID: 39680932

Microdroplet Resuspension Off Surfaces

Overview
Journal Langmuir
Specialty Chemistry
Date 2024 Dec 16
PMID 39680932
Authors
Affiliations
Soon will be listed here.
Abstract

Understanding the resuspension of droplets from surfaces into air is important for elucidating a range of processes such as disease transmission of airborne pathogens and determining environmental contamination and the effectiveness of cleaning procedures. The resuspension condition is defined as the escape velocity of a droplet from a surface. This study investigated the dynamics of microliter-sized droplet resuspension off surfaces utilizing a novel free-fall device. We studied surfaces with three different wettabilities, three droplet volumes, and substrate velocities ranging from 0 to 3.5 m/s for deionized water and viscous droplets representing a prototype saliva substitute. Experimental results provide quantitative results for the increased propensity for drop resuspension for more hydrophobic surfaces, larger droplet volume, and higher velocity. By using high-speed imaging, we segment the resuspension process into four stages: initial equilibrium, deformation, elongation, and breakage. Experimental results are generalized as a machine-learning-derived decision surface, which predicts resuspension by defining a 2D decision boundary in our 3D parameter space. We present a simple physical model, corroborated by computational fluid dynamics simulations, for the dynamics of resuspension that explains the process and is in good agreement with the experiments.

References
1.
Dinic J, Zhang Y, Jimenez L, Sharma V . Extensional Relaxation Times of Dilute, Aqueous Polymer Solutions. ACS Macro Lett. 2022; 4(7):804-808. DOI: 10.1021/acsmacrolett.5b00393. View

2.
ElSherbini A, Jacobi A . Retention forces and contact angles for critical liquid drops on non-horizontal surfaces. J Colloid Interface Sci. 2006; 299(2):841-9. DOI: 10.1016/j.jcis.2006.02.018. View

3.
Xie X, Li Y, Chwang A, Ho P, Seto W . How far droplets can move in indoor environments--revisiting the Wells evaporation-falling curve. Indoor Air. 2007; 17(3):211-25. DOI: 10.1111/j.1600-0668.2007.00469.x. View

4.
Casanova L, Alfano-Sobsey E, Rutala W, Weber D, Sobsey M . Virus transfer from personal protective equipment to healthcare employees' skin and clothing. Emerg Infect Dis. 2008; 14(8):1291-3. PMC: 2600382. DOI: 10.3201/eid1408.080085. View

5.
Nicas M, Nazaroff W, Hubbard A . Toward understanding the risk of secondary airborne infection: emission of respirable pathogens. J Occup Environ Hyg. 2005; 2(3):143-54. PMC: 7196697. DOI: 10.1080/15459620590918466. View