» Articles » PMID: 39655654

Rapid Determination of Chemical Losses in a Microplate Bioassay Using Fluorescence Spectroscopy

Overview
Journal Anal Methods
Specialties Biochemistry
Chemistry
Date 2024 Dec 10
PMID 39655654
Authors
Affiliations
Soon will be listed here.
Abstract

The increase in production and innovation of chemicals that humans interface with has enhanced the need for rapid toxicity testing of new and existing chemicals. This need, along with efforts to reduce animal testing, has led to the development of high-throughput bioassays typically conducted in microplates. These bioassays offer time and resource advantages over traditional animal models; however, significant chemical losses can occur in microplates. Current methods for measuring chemical losses in microplates require extensive sample preparation and highly sensitive instruments. We propose the use of fluorescence spectroscopy to measure chemical losses in high-throughput bioassays as a low resource alternative to the existing methods. A fluorescent plate reader was used to develop methods for quantifying the aqueous concentrations of two chemicals, 2-hydroxynaphthalene and acridine, in microwells of a 96-well microplate. A high-throughput, 5 day embryonic zebrafish bioassay was used as the model bioassay for method development. Chemical losses were attributed to a combination of photodegradation, sorption, and uptake by the zebrafish embryos, kinetics of which were derived from a pseudo-first order model. Chemical uptake amount was calculated to be approximately 50% and 21% of the total chemical amount added for 2-hydroxynaphthalene and acridine, respectively. Unexpected cranial deformities were observed in the embryonic zebrafish, suggesting further investigation of potential additive toxicity of the ultraviolet radiation exposure from fluorescence measurements and chemical exposure is needed. Nonetheless, this novel method provides a rapid, low resource approach to measuring chemical losses in microplates that can be extended to a variety of autofluorescent chemicals and microplate-based bioassays.

References
1.
Zhang W, Xie H, Li Y, Zhou M, Zhou Z, Wang R . The aryl hydrocarbon receptor: A predominant mediator for the toxicity of emerging dioxin-like compounds. J Hazard Mater. 2021; 426:128084. PMC: 9039345. DOI: 10.1016/j.jhazmat.2021.128084. View

2.
Huchthausen J, Konig M, Escher B, Henneberger L . Experimental exposure assessment for cell-based bioassays in 96- and 384-well plates. Front Toxicol. 2023; 5:1221625. PMC: 10411540. DOI: 10.3389/ftox.2023.1221625. View

3.
Grintzalis K, Dai W, Panagiotidis K, Belavgeni A, Viant M . Miniaturising acute toxicity and feeding rate measurements in Daphnia magna. Ecotoxicol Environ Saf. 2017; 139:352-357. DOI: 10.1016/j.ecoenv.2017.02.002. View

4.
Chlebowski A, Tanguay R, Massey Simonich S . Quantitation and prediction of sorptive losses during toxicity testing of polycyclic aromatic hydrocarbon (PAH) and nitrated PAH (NPAH) using polystyrene 96-well plates. Neurotoxicol Teratol. 2016; 57:30-38. PMC: 5454028. DOI: 10.1016/j.ntt.2016.05.001. View

5.
Li Y, Wang H, Xia X, Zhai Y, Lin H, Wen W . Dissolved organic matter affects both bioconcentration kinetics and steady-state concentrations of polycyclic aromatic hydrocarbons in zebrafish (Danio rerio). Sci Total Environ. 2018; 639:648-656. DOI: 10.1016/j.scitotenv.2018.05.067. View