» Articles » PMID: 39627484

Exposure to a 0.9-GHz Electromagnetic Field on Postnatal Days 21-45 May Trigger the Renin-angiotensin System in Male Rat: a Histological and Biochemical Study

Overview
Journal J Mol Histol
Specialty Biochemistry
Date 2024 Dec 3
PMID 39627484
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of this study was to examine the relationship between the renin-angiotensin system (RAS) and histological and biochemical changes occurring in the kidney tissue of male rats exposed to a 0.9 GHz electromagnetic field (EMF). Twelve male rats aged 21 days were randomly assigned to control (C-Gr) and EMF (EMF-Gr) groups. No procedure was performed on C-Gr, while the EMF-Gr rats were exposed to a 0.9 GHz EMF on postnatal days 21-45 (one hour a day for 25 days). Tissues were removed at the end of the experiment and evaluated using biochemical, and histopathological methods. Increased kidney tissue volume and weight and total body weight were determined in the group exposed to EMF. Lipid peroxidation, glutathione, catalase, and superoxide dismutase also increased in the kidney tissue of the EMF-Gr rats. Histopathological evaluation revealed cortical/medullary bleeding/obstruction and widespread fibrosis, dilatation, vacuolization, and degeneration in distal and proximal tubules, decreased and atypical parietal cells, and degeneration in epithelial cells. Additionally, dilated and degenerated glomeruli in the Malpighian body, Bowman's membrane degeneration and degeneration in the vascular pole, podocyte, pedicel and mesangial cells were also observed. As a result of exposure to EMF, oxidative stress, tissue volume and weight increased, and histopathological changes caused the formation of a pathway that triggers RAS in kidney tissues. In conclusion, long-term exposure to 0.9 GHz EMF can activate the renin-angiotensin system in the rat kidney, and we think that such activation may be associated with structural, histopathological, and biochemical changes occurring in renal tissue.

References
1.
Band P, Le N, Macarthur A, Fang R, Gallagher R . Identification of occupational cancer risks in British Columbia: a population-based case-control study of 1129 cases of bladder cancer. J Occup Environ Med. 2005; 47(8):854-8. DOI: 10.1097/01.jom.0000169094.77036.1d. View

2.
Banerjee B, Seth V, Ahmed R . Pesticide-induced oxidative stress: perspectives and trends. Rev Environ Health. 2001; 16(1):1-40. DOI: 10.1515/reveh.2001.16.1.1. View

3.
Bedir R, Tumkaya L, Sehitoglu I, Kalkan Y, Yilmaz A, Sahin O . The effect of exposure of rats during prenatal period to radiation spreading from mobile phones on renal development. Ren Fail. 2015; 37(2):305-9. DOI: 10.3109/0886022X.2014.985995. View

4.
Bodera P, Stankiewicz W, Antkowiak B, Paluch M, Kieliszek J, Sobiech J . Influence of electromagnetic field (1800 MHz) on lipid peroxidation in brain, blood, liver and kidney in rats. Int J Occup Med Environ Health. 2015; 28(4):751-9. DOI: 10.13075/ijomeh.1896.00255. View

5.
Borzoueisileh S, Shabestani Monfared A, Ghorbani H, Mortazavi S, Zabihi E, Pouramir M . Combined Effects of Radiofrequency Electromagnetic Fields and X-Ray in Renal Tissue and Function. Res Rep Urol. 2020; 12:527-532. PMC: 7605663. DOI: 10.2147/RRU.S257365. View