» Articles » PMID: 39589576

Ultrasensitive Electrochemiluminescencent Multivalent Aptamer Sensor Based on Energy and Electron Transfer Dual Quenching Tactics

Overview
Journal Mikrochim Acta
Specialties Biotechnology
Chemistry
Date 2024 Nov 26
PMID 39589576
Authors
Affiliations
Soon will be listed here.
Abstract

An efficient "on-off-on" electrochemiluminescence (ECL) aptasensor utilizing dual-mechanism quenching was constructed for detecting furanyl fentanyl (FuF). The first signal "on" state was achieved by novel dual-ligand zinc metal-organic frameworks (Zn-MOFs), which were synthesized by self-assembly reaction using zinc atom clusters as metal nodes, achieving strong and stable ECL emission. The "off" state was realized by the energy and electron quenching effect of copper-doped WO. Specifically, in addition to the overlap of the UV-Vis spectrum, energy transfer existed between the acceptor and donor after doping copper. Therefore, copper created a "highway" for electron transfer between the donor and acceptor, which greatly improved the quenching efficiency. Simultaneously, employing multivalent aptamers as capture probes augmented the binding affinity and probability of association between aptamer and target through a synergistic multivalent effect. Consequently, the second "on" state was the ECL signal restored by introducing FuF. Benefiting from the combination of the multivalent aptamers strategy with the "on-off-on" design, the developed aptasensor showed excellent linearity (1.0 × 10 to 1.0 × 10 g/L) with a low limit of detection of 5.5 × 10 g/L (S/N = 3). Additionally, it demonstrates a relative standard deviation (RSD) of less than 5% and good recovery ranging from 97.6 to 102%. The proposed aptasensor presents considerable potential for rapid, sensitive, and accurate determination of FuF.

References
1.
Misailidi N, Papoutsis I, Nikolaou P, Dona A, Spiliopoulou C, Athanaselis S . Fentanyls continue to replace heroin in the drug arena: the cases of ocfentanil and carfentanil. Forensic Toxicol. 2018; 36(1):12-32. PMC: 5754389. DOI: 10.1007/s11419-017-0379-4. View

2.
Goswami S, Brady J, Jordan D, Li G . Intraoperative cardiac arrests in adults undergoing noncardiac surgery: incidence, risk factors, and survival outcome. Anesthesiology. 2012; 117(5):1018-26. DOI: 10.1097/ALN.0b013e31827005e9. View

3.
Day J, Slawson M, Lugo R, Wilkins D . Analysis of fentanyl and norfentanyl in human plasma by liquid chromatography-tandem mass spectrometry using electrospray ionization. J Anal Toxicol. 2003; 27(7):513-6. DOI: 10.1093/jat/27.7.513. View

4.
Bade R, Abdelaziz A, Nguyen L, Pandopulos A, White J, Gerber C . Determination of 21 synthetic cathinones, phenethylamines, amphetamines and opioids in influent wastewater using liquid chromatography coupled to tandem mass spectrometry. Talanta. 2019; 208:120479. DOI: 10.1016/j.talanta.2019.120479. View

5.
Haddad A, Comanescu M, Green O, Kubic T, Lombardi J . Detection and Quantitation of Trace Fentanyl in Heroin by Surface-Enhanced Raman Spectroscopy. Anal Chem. 2018; 90(21):12678-12685. DOI: 10.1021/acs.analchem.8b02909. View