» Articles » PMID: 39550825

Visual Performance of a New Trifocal Intraocular Lens Design Evaluated with a Clinical Adaptative Optics Visual Simulator

Overview
Journal J Optom
Specialty Ophthalmology
Date 2024 Nov 17
PMID 39550825
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: The digital transformation of daily routines has increased visual demands, especially at intermediate and near distances. The Devil multifocal intraocular lens (MIOL) design was developed to enhance intermediate visual performance. This design is a novel trifocal intraocular lens inspired by the fractal structure known as the 'Devil's staircase'. The aim of this research is to evaluate the visual performance of the Devil MIOL design in real patients.

Methods: The visual acuity defocus curve was obtained from 25 eyes of healthy volunteers using the Visual Adaptive Optics Simulator (VAO, Voptica SL, Murcia, Spain). Additionally, images of optotypes simulating those seen through the Devil MIOL design were captured to qualitatively illustrate optotype perception at different vergence values.

Results: Mean visual acuity values of the evaluation were 0.03 logMAR at 0.00 D vergence, 0.10 logMAR at +1.50 D vergence, and 0.11 logMAR at +3.00 D vergence, corresponding to far (optical infinity), intermediate (66.7 cm), and near foci (33.3 cm), respectively. The experimental outcomes were indeed slightly better than numerical results obtained previously in a model eye.

Conclusions: The Devil MIOL design provides satisfactory visual acuity across three primary foci and produces extended depth of focus between the intermediate and near foci.

References
1.
Ribeiro F, Ferreira T . Comparison of clinical outcomes of 3 trifocal IOLs. J Cataract Refract Surg. 2020; 46(9):1247-1252. DOI: 10.1097/j.jcrs.0000000000000212. View

2.
Alio J, Plaza-Puche A, Alio Del Barrio J, Amat-Peral P, Ortuno V, Yebana P . Clinical outcomes with a diffractive trifocal intraocular lens. Eur J Ophthalmol. 2018; 28(4):419-424. DOI: 10.1177/1120672118762231. View

3.
Monsoriu J, Furlan W, Saavedra G, Gimenez F . Devil's lenses. Opt Express. 2009; 15(21):13858-64. DOI: 10.1364/oe.15.013858. View

4.
Liou H, Brennan N . Anatomically accurate, finite model eye for optical modeling. J Opt Soc Am A Opt Image Sci Vis. 1997; 14(8):1684-95. DOI: 10.1364/josaa.14.001684. View

5.
Montagud-Martinez D, Ferrando V, Martinez-Espert A, Garcia-Delpech S, Monsoriu J, Furlan W . In Vitro Chromatic Performance of Three Presbyopia-Correcting Intraocular Lenses with Different Optical Designs. J Clin Med. 2022; 11(5). PMC: 8910850. DOI: 10.3390/jcm11051212. View