» Articles » PMID: 39451982

Assessment of Interrater Reliability and Accuracy of Cerebral Aneurysm Morphometry Using 3D Virtual Reality, 2D Digital Subtraction Angiography, and 3D Reconstruction: A Randomized Comparative Study

Overview
Journal Brain Sci
Publisher MDPI
Date 2024 Oct 25
PMID 39451982
Authors
Affiliations
Soon will be listed here.
Abstract

Background/objectives: Detailed morphometric analysis of an aneurysm and the related vascular bifurcation are critical factors when determining rupture risk and planning treatment for unruptured intracranial aneurysms (UIAs). The standard visualization of digital subtraction angiography (DSA) and its 3D reconstruction on a 2D monitor provide precise measurements but are subject to variability based on the rater. Visualization using virtual (VR) and augmented reality platforms can overcome those limitations. It is, however, unclear whether accurate measurements of the aneurysm and adjacent arterial branches can be obtained on VR models. This study aimed to assess interrater reliability and compare measurements between 3D VR, standard 2D DSA, and 3D DSA reconstructions, evaluating the reliability and accuracy of 3D VR as a measurement tool.

Methods: A pool of five neurosurgeons performed three individual analyses on each of the ten UIA cases, measuring them in completely immersed 3D VR and the standard on-screen format (2D DSA and 3D reconstruction). This resulted in three independent measurements per modality for each case. Interrater reliability of measurements and morphology characterization, comparative differences, measurement duration, and VR user experience were assessed.

Results: Interrater reliability for 3D VR measurements was significantly higher than for 3D DSA measurements (3D VR mean intraclass correlation coefficient [ICC]: 0.69 ± 0.22 vs. 3D DSA mean ICC: 0.36 ± 0.37, = 0.042). No significant difference was observed between 3D VR and 2D DSA (3D VR mean ICC: 0.69 ± 0.22 vs. 2D DSA mean ICC: 0.43 ± 0.31, = 0.12). A linear mixed-effects model showed no effect of 3D VR and 3D DSA (95% CI = -0.26-0.28, = 0.96) or 3D VR and 2D DSA (95% CI = -0.02-0.53, = 0.066) on absolute measurements of the aneurysm in the anteroposterior, mediolateral, and craniocaudal dimensions.

Conclusions: 3D VR technology allows for reproducible, accurate, and reliable measurements comparable to measurements performed on a 2D screen. It may also potentially improve precision for measurements of non-planar aneurysm dimensions.

References
1.
Briganti F, Tortora M, Loiudice G, Tarantino M, Guida A, Buono G . Utility of virtual stenting in treatment of cerebral aneurysms by flow diverter devices. Radiol Med. 2023; 128(4):480-491. DOI: 10.1007/s11547-023-01620-x. View

2.
Greving J, Wermer M, Brown Jr R, Morita A, Juvela S, Yonekura M . Development of the PHASES score for prediction of risk of rupture of intracranial aneurysms: a pooled analysis of six prospective cohort studies. Lancet Neurol. 2013; 13(1):59-66. DOI: 10.1016/S1474-4422(13)70263-1. View

3.
Greuter L, De Rosa A, Cattin P, Croci D, Soleman J, Guzman R . Randomized study comparing 3D virtual reality and conventional 2D on-screen teaching of cerebrovascular anatomy. Neurosurg Focus. 2021; 51(2):E18. DOI: 10.3171/2021.5.FOCUS21212. View

4.
van Rooij W, Sprengers M, de Gast A, Peluso J, Sluzewski M . 3D rotational angiography: the new gold standard in the detection of additional intracranial aneurysms. AJNR Am J Neuroradiol. 2008; 29(5):976-9. PMC: 8128578. DOI: 10.3174/ajnr.A0964. View

5.
Etminan N, Brown Jr R, Beseoglu K, Juvela S, Raymond J, Morita A . The unruptured intracranial aneurysm treatment score: a multidisciplinary consensus. Neurology. 2015; 85(10):881-9. PMC: 4560059. DOI: 10.1212/WNL.0000000000001891. View