Speckle Vibrometry for Contactless Instantaneous Heart Rate and Respiration Rate Monitoring on Mechanically Ventilated Patients

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2024 Oct 16
PMID 39409414
Authors
Affiliations
Soon will be listed here.
Abstract

: Contactless monitoring of instantaneous heart rate and respiration rate has a significant clinical relevance. This work aims to use Speckle Vibrometry (i.e., based on the secondary laser speckle effect) to contactlessly measure these two vital signs in an intensive care unit. : In this work, we propose an algorithm for the estimation of instantaneous heart rate and respiration rate from mechanically ventilated patients. The algorithm uses multiple regions, principal component analysis, and dominant angle analysis. A semi-automated peak detection method is implemented to precisely label the aortic valve opening peak within the cardiac waveform. : Compared with electrocardiography, the present work achieves limits of agreement of [-2.19, 1.73] beats per minute of instantaneous heart rate. The measurement spot is on the chest covered with two to three layers of duvet blankets. Compared with the airway flow signal measured by the mechanical ventilator, the present work achieves limits of agreement of [-0.68, 0.46] respirations per minute of instantaneous respiration rate. : These results showcased Speckle Vibrometry's potential in vital sign monitoring in a clinical setting. : This is the first human clinical study for Speckle Vibrometry.

References
1.
Bland J, Altman D . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1(8476):307-10. View

2.
Que S, Verkruijsse W, van Gastel M, Stuijk S . Contactless Heartbeat Measurement Using Speckle Vibrometry. Annu Int Conf IEEE Eng Med Biol Soc. 2022; 2022:4604-4610. DOI: 10.1109/EMBC48229.2022.9871712. View

3.
Jafari Tadi M, Lehtonen E, Saraste A, Tuominen J, Koskinen J, Teras M . Gyrocardiography: A New Non-invasive Monitoring Method for the Assessment of Cardiac Mechanics and the Estimation of Hemodynamic Variables. Sci Rep. 2017; 7(1):6823. PMC: 5533710. DOI: 10.1038/s41598-017-07248-y. View

4.
Kranjec J, Begus S, Gersak G, Sinkovec M, Drnovsek J, Hudoklin D . Design and Clinical Evaluation of a Non-Contact Heart Rate Variability Measuring Device. Sensors (Basel). 2017; 17(11). PMC: 5712847. DOI: 10.3390/s17112637. View

5.
Toften S, Kjellstadli J, Thu O, Ellingsen O . Noncontact Longitudinal Respiratory Rate Measurements in Healthy Adults Using Radar-Based Sleep Monitor (Somnofy): Validation Study. JMIR Biomed Eng. 2024; 7(2):e36618. PMC: 11041471. DOI: 10.2196/36618. View