Optimising Flow Without Congestion Using the Venous-arterial Doppler Enhanced Resuscitation Framework

Overview
Date 2024 Sep 27
PMID 39328256
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Ultrasonography as a guide for intravenous (IV) fluid therapy is increasingly accepted within the spheres of acute care. Initial investigations and protocols often focused on measures of arterial flow as an objective approach for personalising organ 'perfusion.' More recently, and with literature associating excessive IV fluid with adverse outcomes, venous ultrasound as a measure of organ 'congestion' is taking hold. Yet, arterial (i.e., 'perfusion') and venous (i.e., 'congestion') Doppler ultrasound measures are often performed separately and can be time-consuming, especially for novices.

Methods: We report a case, wherein venous and arterial Doppler were simultaneously measured using a wireless, wearable ultrasound as a means to optimise flow without congestion.

Results: Before IV volume expansion, the patient had Doppler measures consistent with low central venous pressure (CVP) and stroke volume (SV). Following IV volume expansion, venous Doppler remained the same; however, carotid corrected flow time (ccFT) increased significantly.

Conclusion: A framework for venous-arterial Doppler enhanced resuscitation (VADER) can be used to guide IV volume in patients at risk for venous congestion.

References
1.
Kenny J, Eibl J, Mackenzie D, Barjaktarevic I . Guidance of IV Fluid by Ultrasound Will Improve With Technology. Chest. 2022; 161(2):e132-e133. DOI: 10.1016/j.chest.2021.09.013. View

2.
Kenny J, Prager R, Rola P, Haycock K, Gibbs S, Johnston D . Simultaneous Venous-Arterial Doppler Ultrasound During Early Fluid Resuscitation to Characterize a Novel Doppler Starling Curve: A Prospective Observational Pilot Study. J Intensive Care Med. 2024; 39(7):628-635. PMC: 11188059. DOI: 10.1177/08850666231224396. View

3.
Munoz F, Born P, Bruna M, Ulloa R, Gonzalez C, Philp V . Coexistence of a fluid responsive state and venous congestion signals in critically ill patients: a multicenter observational proof-of-concept study. Crit Care. 2024; 28(1):52. PMC: 10877871. DOI: 10.1186/s13054-024-04834-1. View

4.
Kerrebijn I, Atwi S, Horner C, Elfarnawany M, Eibl A, Eibl J . Correlation between changing carotid artery corrected flow time and ascending aortic Doppler flow velocity. Br J Anaesth. 2023; 131(6):e192-e195. DOI: 10.1016/j.bja.2023.09.016. View

5.
Kenny J, Horner C, Elfarnawany M, Eibl A, Eibl J . Carotid Artery Corrected Flow Time Measured by Wearable Doppler Ultrasound Accurately Detects Changing Stroke Volume During the Passive Leg Raise in Ambulatory Volunteers. Front Biosci (Elite Ed). 2023; 15(2):12. DOI: 10.31083/j.fbe1502012. View