» Articles » PMID: 39308575

Arthroscopic Anterior Cruciate Ligament Avulsion Fixation With a Knotless Suture Anchor: A Minimalistic Approach

Overview
Journal Arthrosc Tech
Publisher Elsevier
Date 2024 Sep 23
PMID 39308575
Authors
Affiliations
Soon will be listed here.
Abstract

This technical note outlines a minimalist arthroscopic approach to anterior cruciate ligament avulsion fracture fixation using a bioabsorbable knotless suture anchor. This method represents a less invasive alternative to traditional techniques, catering specifically to fractures classified as Meyers and McKeever type II or III. The procedure is performed through standard anterolateral and anteromedial portals without the need for additional incisions or bone tunnel drilling, making it particularly suitable for children and adolescent patients with open physes. The technique involves the use of a suture hook to pass a double-stranded suture through the anterior cruciate ligament, anchored eccentrically to the anterior tibial incline with a knotless suture anchor. This approach allows for anatomic reduction with adjustable tension and without the potential risk of iatrogenic osteochondral injury. Nonetheless, it should be acknowledged that prospective biomechanical studies and larger patient samples are necessary to validate this technique compared with existing fixation methods.

References
1.
Giuliani J, Kilcoyne K, Rue J . Anterior cruciate ligament anatomy: a review of the anteromedial and posterolateral bundles. J Knee Surg. 2009; 22(2):148-54. DOI: 10.1055/s-0030-1247742. View

2.
Jang K, Bae J, Kim J, Wang J . Novel arthroscopic fixation method for anterior cruciate ligament tibial avulsion fracture with accompanying detachment of the anterior horn of the lateral meniscus: three-point suture fixation. Injury. 2013; 44(8):1028-32. DOI: 10.1016/j.injury.2012.12.008. View

3.
Yoon J, Park C, Lee D . Arthroscopic suture bridge fixation technique with multiple crossover ties for posterior cruciate ligament tibial avulsion fracture. Knee Surg Sports Traumatol Arthrosc. 2016; 26(3):912-918. DOI: 10.1007/s00167-016-4339-z. View

4.
Yuan L, Shi R, Chen Z, Ding W, Tan H . The most economical arthroscopic suture fixation for tibial intercondylar eminence avulsion fracture without any implant. J Orthop Surg Res. 2022; 17(1):327. PMC: 9233839. DOI: 10.1186/s13018-022-03219-w. View

5.
Bauer A, Steffen R, Warnick D . A Technique for Arthroscopic Fixation of Tibial Eminence Avulsion Fractures: A Physeal-Sparing Construct With All-Suture Anchor Bridge Fixation. Arthrosc Tech. 2024; 13(2):102854. PMC: 10907912. DOI: 10.1016/j.eats.2023.09.029. View