» Articles » PMID: 39296469

Human-Sized Organ Machine Perfusion: A Systematic Review on the Added Value of Medical Imaging for Organ Condition Assessment

Overview
Journal Transpl Int
Specialty General Surgery
Date 2024 Sep 19
PMID 39296469
Authors
Affiliations
Soon will be listed here.
Abstract

Machine perfused organs offer an excellent experimental platform, e.g., for studying organ physiology and for conducting pre-clinical trials for drug delivery. One main challenge in machine perfusion is the accurate assessment of organ condition. Assessment is often performed using viability markers, i.e., lactate concentrations and blood gas analysis. Nonetheless, existing markers for condition assessment can be inconclusive, and novel assessment methods remain of interest. Over the last decades, several imaging modalities have given unique insights into the assessment of organ condition. A systematic review was conducted according to accepted guidelines to evaluate these medical imaging methods, focussed on literature that use machine perfused human-sized organs, that determine organ condition with medical imaging. A total of 18 out of 1,465 studies were included that reported organ condition results in perfused hearts, kidneys, and livers, using both conventional viability markers and medical imaging. Laser speckle imaging, ultrasound, computed tomography, and magnetic resonance imaging were used to identify local ischemic regions and quantify intra-organ perfusion. A detailed investigation of metabolic activity was achieved using P magnetic resonance imaging and near-infrared spectroscopy. The current review shows that medical imaging is a powerful tool to assess organ condition.

References
1.
Bona M, Wyss R, Arnold M, Mendez-Carmona N, Sanz M, Gunsch D . Cardiac Graft Assessment in the Era of Machine Perfusion: Current and Future Biomarkers. J Am Heart Assoc. 2021; 10(4):e018966. PMC: 7955334. DOI: 10.1161/JAHA.120.018966. View

2.
Piscaglia F, Bolondi L . The safety of Sonovue in abdominal applications: retrospective analysis of 23188 investigations. Ultrasound Med Biol. 2006; 32(9):1369-75. DOI: 10.1016/j.ultrasmedbio.2006.05.031. View

3.
Park S, Kim C, Park B, Kim S, Lee S, Huh W . Assessment of early renal allograft dysfunction with blood oxygenation level-dependent MRI and diffusion-weighted imaging. Eur J Radiol. 2014; 83(12):2114-2121. DOI: 10.1016/j.ejrad.2014.09.017. View

4.
Heeman W, Maassen H, Calon J, Goor H, Leuvenink H, van Dam G . Real-time visualization of renal microperfusion using laser speckle contrast imaging. J Biomed Opt. 2021; 26(5). PMC: 8140613. DOI: 10.1117/1.JBO.26.5.056004. View

5.
Vaillant F, Magat J, Bour P, Naulin J, Benoist D, Loyer V . Magnetic resonance-compatible model of isolated working heart from large animal for multimodal assessment of cardiac function, electrophysiology, and metabolism. Am J Physiol Heart Circ Physiol. 2016; 310(10):H1371-80. DOI: 10.1152/ajpheart.00825.2015. View