» Articles » PMID: 39279010

Morphologic Features of Iris in Highly Myopic Eyes Based on a Novel Swept-source Optical Coherence Tomography

Overview
Journal Eye (Lond)
Specialty Ophthalmology
Date 2024 Sep 15
PMID 39279010
Authors
Affiliations
Soon will be listed here.
Abstract

Background: To investigate the morphologic features of iris in the highly myopic (HM) eyes using a novel swept-source optical coherence tomography (SS-OCT).

Methods: In this retrospective case-control study, 100 eyes of 100 patients scheduled to have cataract surgery were included, categorized into the control (22 mm< AL < 24.5 mm) and HM (AL ≥ 26 mm) groups. Iris volume (IV), area of anterior iris surface (IS), area of posterior IS, and average iris thickness (IT), as well as anterior chamber volume (ACV) and trabecular-iris space at 500 µm (TISA 500) were evaluated using SS-OCT. The associated factors with morphologic features of iris were also investigated.

Results: The HM group showed significantly larger IV and area of anterior and posterior IS than the control group (all P < 0.001), while no difference was identified in IT between the groups. Similar trend in IV was seen in the superior and nasal segments, and area of anterior and posterior IS showed similar trends in all segments except the temporal segment. The IV, area of anterior and posterior IS were all positively correlated with AL (all P < 0.001). Multivariate linear regression revealed that a larger IV was associated with greater ACV. Both larger areas of anterior IS and posterior IS were associated with male, longer AL, greater ACV, and smaller TISA 500.

Conclusions: The HM eyes showed larger IV and area of IS than the control eyes, indicating a coronal expansion of the iris with AL. Iris morphology correlated with anterior chamber angle configuration.

References
1.
Zhu X, Zhang K, He W, Yang J, Sun X, Jiang C . Proinflammatory status in the aqueous humor of high myopic cataract eyes. Exp Eye Res. 2015; 142:13-8. DOI: 10.1016/j.exer.2015.03.017. View

2.
Mak H, Xu G, Leung C . Imaging the iris with swept-source optical coherence tomography: relationship between iris volume and primary angle closure. Ophthalmology. 2013; 120(12):2517-2524. DOI: 10.1016/j.ophtha.2013.05.009. View

3.
Invernizzi A, Giardini P, Cigada M, Viola F, Staurenghi G . Three-Dimensional Morphometric Analysis of the Iris by Swept-Source Anterior Segment Optical Coherence Tomography in a Caucasian Population. Invest Ophthalmol Vis Sci. 2015; 56(8):4796-801. DOI: 10.1167/iovs.15-16483. View

4.
Yim-Lui Cheung C, Liu S, Weinreb R, Liu J, Li H, Leung D . Dynamic analysis of iris configuration with anterior segment optical coherence tomography. Invest Ophthalmol Vis Sci. 2010; 51(8):4040-6. DOI: 10.1167/iovs.09-3941. View

5.
Wei L, He W, Meng J, Qian D, Lu Y, Zhu X . Evaluation of the White-to-White Distance in 39,986 Chinese Cataractous Eyes. Invest Ophthalmol Vis Sci. 2021; 62(1):7. PMC: 7794278. DOI: 10.1167/iovs.62.1.7. View