» Articles » PMID: 39279004

Mandibular Overdentures Retained by 1 or 2 Implants: a 5-year Randomized Clinical Trial on Implant Stability and Peri-implant Outcomes

Overview
Specialty Dentistry
Date 2024 Sep 15
PMID 39279004
Authors
Affiliations
Soon will be listed here.
Abstract

Aim: This is a report of the 5-year results of a two-group parallel randomized clinical trial comparing longitudinal implant stability, and clinical and radiographic peri-implant outcomes of mandibular overdentures retained by one (1-IOD group) or two (2-IOD group) implants.

Methods: All participants received 4.1 mm diameter tissue-level implants (Straumann Standard Plus - SLActive, Institut Straumann AG), installed in the mandible midline (1-IOD; n = 23) or the lateral incisor-canine area bilaterally (2-IOD; n = 24), and loaded after 3 weeks. Implant Stability Quotient (ISQ) was measured using a resonance frequency device (Osstell Mentor, Integration Diagnostics) at implant placement, after three weeks (loading), and at the 6-month, 1-, 3-, and 5-year follow-ups. Marginal bone loss and clinical implant outcomes (plaque, calculus, suppuration and bleeding) were assessed periodically up to 5 years after loading.

Results: Only minor changes in marginal bone level were observed after 5 years (mean = 0.37; SD = 0.44 mm), and satisfactory and stable peri-implant parameters were observed throughout the 5-year follow-up. No significant differences between groups were found. Overall, the mean primary implant stability was considered high (> 70) for the two groups (1-IOD = 78.1 ± 4.5; 2-IOD = 78.0 ± 5.8). No noticeable changes were observed between implant insertion and loading. A marked increase was observed from insertion to the 6-month follow-up - the mean difference for the 1-IOD group was + 5.5 ± 5.5 (Effect size = 1.00), while for the 2-IOD group, the mean difference was + 6.0 ± 5.6 (Effect size = 1.08). No relevant changes were observed throughout the follow-up periods up to 5 years. Linear mixed-effect model regression showed no influence of the bone-related variables (p > 0.05) and the number of implants (p = 0.087), and a significant effect of the time variable (p < 0.001).

Conclusion: Satisfactory peri-implant outcomes and stable secondary stability suggest good clinical performance and successful long-term osseointegration of the implants for single and two-implant mandibular overdentures. Using a single implant to retain a mandibular overdenture does not seem to result in detrimental implant loading over the five years of overdenture use.

Clinical Relevance: This study corroborates the use of a single implant to retain a mandibular denture.

Citing Articles

Carbon fiber-reinforced PEEK as a framework material for single implant-retained mandibular overdentures.

Borges G, Mesquita M, Matias L, Barbin T, Machado L, Ricardo Barao V Braz Oral Res. 2025; 39:e018.

PMID: 39936717 PMC: 11808703. DOI: 10.1590/1807-3107bor-2025.vol39.018.

References
1.
de Resende G, Dias A, Leles J, de Souza J, Leles C . Postsurgical oral symptoms after insertion of one or two implants for mandibular overdentures: short-term results of a randomized clinical trial. Int J Implant Dent. 2021; 7(1):38. PMC: 8079530. DOI: 10.1186/s40729-021-00321-2. View

2.
Rodrigo D, Aracil L, Martin C, Sanz M . Diagnosis of implant stability and its impact on implant survival: a prospective case series study. Clin Oral Implants Res. 2009; 21(3):255-61. DOI: 10.1111/j.1600-0501.2009.01820.x. View

3.
Cawood J, Howell R . A classification of the edentulous jaws. Int J Oral Maxillofac Surg. 1988; 17(4):232-6. DOI: 10.1016/s0901-5027(88)80047-x. View

4.
H H, G W, E H . The clinical significance of implant stability quotient (ISQ) measurements: A literature review. J Oral Biol Craniofac Res. 2020; 10(4):629-638. PMC: 7494467. DOI: 10.1016/j.jobcr.2020.07.004. View

5.
Schulz K, Altman D, Moher D . CONSORT 2010 Statement: updated guidelines for reporting parallel group randomised trials. BMC Med. 2010; 8:18. PMC: 2860339. DOI: 10.1186/1741-7015-8-18. View