» Articles » PMID: 39242515

Ultrasonic Assessment of Gastric Solid Contents in Patients Undergoing Upper Endoscope with Sedation

Overview
Journal BMC Anesthesiol
Publisher Biomed Central
Specialty Anesthesiology
Date 2024 Sep 6
PMID 39242515
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Perioperative reflux aspiration presents a grave concern during sedation or general anesthesia, particularly when solid gastric contents prompt acute upper respiratory obstruction, potentially resulting in fatal consequences for patients. Currently, there are limited means for promptly assessing solid gastric contents in clinical settings. Therefore, this study examined the efficacy of ultrasound assessment for solid gastric contents, offering a rapid and non-invasive approach for early detection and decision-making regarding interventions.

Methods: The study included 400 patients scheduled for upper endoscopy procedures, which encompassed both gastroscope and gastroscope combined colonoscopy examinations with sedation. Ultrasound scanning of the antrum was performed while patients were positioned semi-sitting or in the right lateral decubitus (RLD) posture. The evaluation of solid gastric contents relied on direct visual observation during endoscopy. Gastric volume measurement occurred subsequent to endoscopic suction of gastric contents. Receiver operating characteristic curves were utilized to assess the effectiveness of ultrasonography in discerning solid contents.

Result: Seven patients undergoing gastroscope with sedation were found to have solid gastric contents. The sensitivity, specificity, positive predictive value, and negative predictive value of the ultrasound qualitative evaluation of solid contents were 85.7%, 99%, 60%, and 99.7%, respectively.

Conclusion: Solid stomach contents can be evaluated qualitatively with reasonable accuracy using ultrasonography. Additionally, in patients undergoing upper endoscopy and assessed to have solid gastric contents with ultrasound, administration of mild sedation is recommended.

Trial Registration: www.chictr.org.cn (ChiCTR2100048994); registered 19/07/2021.

Citing Articles

Ultrasonographic assessment of gastric and gallbladder dynamics in human health and disease.

Di Ciaula A, Khalil M, Portincasa P Intern Emerg Med. 2025; .

PMID: 40016490 DOI: 10.1007/s11739-025-03905-7.

References
1.
Raidoo D, Rocke D, Brock-Utne J, Marszalek A, Engelbrecht H . Critical volume for pulmonary acid aspiration: reappraisal in a primate model. Br J Anaesth. 1990; 65(2):248-50. DOI: 10.1093/bja/65.2.248. View

2.
Hakak S, McCaul C, Crowley L . Ultrasonographic evaluation of gastric contents in term pregnant women fasted for six hours. Int J Obstet Anesth. 2018; 34:15-20. DOI: 10.1016/j.ijoa.2018.01.004. View

3.
Deloose E, Janssen P, Depoortere I, Tack J . The migrating motor complex: control mechanisms and its role in health and disease. Nat Rev Gastroenterol Hepatol. 2012; 9(5):271-85. DOI: 10.1038/nrgastro.2012.57. View

4.
Van de Putte P, Vernieuwe L, Jerjir A, Verschueren L, Tacken M, Perlas A . When fasted is not empty: a retrospective cohort study of gastric content in fasted surgical patients†. Br J Anaesth. 2017; 118(3):363-371. DOI: 10.1093/bja/aew435. View

5.
Bi D, Choi C, League J, Camilleri M, Prichard D . Food Residue During Esophagogastroduodenoscopy Is Commonly Encountered and Is Not Pathognomonic of Delayed Gastric Emptying. Dig Dis Sci. 2020; 66(11):3951-3959. DOI: 10.1007/s10620-020-06718-0. View