» Articles » PMID: 39223223

Fuchs' Endothelial Corneal Dystrophy Evaluation Using a High-resolution Wavefront Sensor

Overview
Journal Sci Rep
Specialty Science
Date 2024 Sep 2
PMID 39223223
Authors
Affiliations
Soon will be listed here.
Abstract

This study aims to evaluate the applicability of the high-resolution WaveFront Phase Imaging Sensor (WFPI) in eyes with Fuchs' Endothelial Corneal Dystrophy (FECD) through qualitative and quantitative analysis using a custom-designed Automatic Guttae Detection Method (AGDM). The ocular phase was measured using the t eyede aberrometer and then was processed to obtain its High-Pass Filter Map (HPFM). The subjects were pathological and healthy patients from the Fundación Jiménez-Díaz Hospital (Madrid, Spain). The AGDM was developed and applied in pupils with 3 and 5 mm of diameter. A set of metrics were extracted and evaluated like the Root-Mean-Square error (RMS), Number of guttae, Guttae Area, and Area of Delaunay Triangulation (DT). Finally, a Support Vector Machine (SVM) model was trained to classify between pathological and healthy eyes. Quantitatively, the HPFM reveals a dark spots pattern according to the ophthalmologist's description of the slit-lamp examination of guttae distribution. There were significant statistical differences in all the metrics when FECD and Healthy groups were compared using the same pupil size; but comparing both pupil sizes for the same group there were significant differences in most of the variables. This sensor is a value tool to objectively diagnose and monitor this pathology through wavefront phase changes.

References
1.
Mustonen R, McDonald M, Srivannaboon S, Tan A, Doubrava M, Kim C . In vivo confocal microscopy of Fuchs' endothelial dystrophy. Cornea. 1998; 17(5):493-503. DOI: 10.1097/00003226-199809000-00006. View

2.
Repp D, Hodge D, Baratz K, McLaren J, Patel S . Fuchs' endothelial corneal dystrophy: subjective grading versus objective grading based on the central-to-peripheral thickness ratio. Ophthalmology. 2013; 120(4):687-94. PMC: 3618600. DOI: 10.1016/j.ophtha.2012.09.022. View

3.
Giasson C, Graham A, Blouin J, Solomon L, Gresset J, Melillo M . Morphometry of cells and guttae in subjects with normal or guttate endothelium with a contour detection algorithm. Eye Contact Lens. 2005; 31(4):158-65. DOI: 10.1097/01.icl.0000165286.05080.23. View

4.
van Dam M, Lane R . Extended analysis of curvature sensing. J Opt Soc Am A Opt Image Sci Vis. 2002; 19(7):1390-7. DOI: 10.1364/josaa.19.001390. View

5.
Elhalis H, Azizi B, Jurkunas U . Fuchs endothelial corneal dystrophy. Ocul Surf. 2010; 8(4):173-84. PMC: 3061348. DOI: 10.1016/s1542-0124(12)70232-x. View