» Articles » PMID: 39207609

Feasibility of a Deep-inspiration Breath-hold [F]AlF-NOTA-LM3 PET/CT Imaging on Upper-abdominal Lesions in NET Patients: in Comparison with Respiratory-gated PET/CT

Overview
Journal EJNMMI Phys
Specialty Radiology
Date 2024 Aug 29
PMID 39207609
Authors
Affiliations
Soon will be listed here.
Abstract

Purposes: To explore the clinical feasibility and efficacy of a deep inspiration breath-hold (BH) PET/CT using [F]AlF-NOTA-LM3 on upper abdominal lesions in patients with neuroendocrine tumors (NETs).

Methods: Twenty-three patients underwent a free-breath (FB) whole-body PET/CT, including a 10 min/bed scan for the upper abdomen with a vital signal monitoring for respiratory gating (RG) followed by a 20-second BH PET/CT covering the same axial range. For the upper abdomen bed, the following PET series was reconstructed: a 2-min FB PET; RG PET (6 bins); a 20-second and 15-second BH PET (BH_15 and BH_20). Semi-quantitative analysis was performed to compare liver SUV, lesion SUV, MTV, its percentage difference and target-to-background ratio (TBR) between both BH PET and RG PET images. Subgroup analysis considered lesion location, MTV and SUV. A 5-point Likert scale was used to perform visual analysis and any missed or additional lesions were identified compared with RG PET.

Results: Quantitative analysis on overall lesions (n = 78) revealed higher SUV and TBR, and smaller MTV for both BH PET compared to FB and RG PET, with lesion location-specific variations. Neither significant difference was observed in all metrics between RG and FB PET in larger lesions, nor in MTV in lower-uptake lesions. However, both BH PET significantly enhanced these measurements. In the visual analysis, both BH PET showed noninferior performance to RG PET, and were evaluated clinically acceptable. Additional and missed lesions were observed in FB and both BH PET compared with RG PET, but didn't alter the clinical management. The BH_15 PET showed comparable performance to BH_20 PET in any comparison.

Conclusion: The BH PET/CT using [F]AlF-NOTA-LM3 is effective in detecting upper abdominal lesions, offering more accurate quantitative measurements. Using a novel PET/CT scanner, a 15-second BH PET can provide comparable and superior performance to RG PET, indicating potential feasibility in clinical routines.

References
1.
Kang S, Moon B, Kim H, Yoon H, Kim B . The impact of data-driven respiratory gating in clinical F-18 FDG PET/CT: comparison of free breathing and deep-expiration breath-hold CT protocol. Ann Nucl Med. 2021; 35(3):328-337. DOI: 10.1007/s12149-020-01574-4. View

2.
Hope T, Allen-Auerbach M, Bodei L, Calais J, Dahlbom M, Dunnwald L . SNMMI Procedure Standard/EANM Practice Guideline for SSTR PET: Imaging Neuroendocrine Tumors. J Nucl Med. 2023; 64(2):204-210. DOI: 10.2967/jnumed.122.264860. View

3.
Leupe H, Ahenkorah S, Dekervel J, Unterrainer M, Van Cutsem E, Verslype C . F-Labeled Somatostatin Analogs as PET Tracers for the Somatostatin Receptor: Ready for Clinical Use. J Nucl Med. 2023; 64(6):835-841. DOI: 10.2967/jnumed.123.265622. View

4.
Walker M, Morgan A, Bradley K, McGowan D . Data-Driven Respiratory Gating Outperforms Device-Based Gating for Clinical F-FDG PET/CT. J Nucl Med. 2020; 61(11):1678-1683. PMC: 7116324. DOI: 10.2967/jnumed.120.242248. View

5.
Liu M, Ren C, Zhang H, Zhang Y, Huang Z, Jia R . Evaluation of the safety, biodistribution, dosimetry of [F]AlF-NOTA-LM3 and head-to-head comparison with [Ga]Ga-DOTATATE in patients with well-differentiated neuroendocrine tumors: an interim analysis of a prospective trial. Eur J Nucl Med Mol Imaging. 2024; 51(12):3719-3730. DOI: 10.1007/s00259-024-06790-y. View