» Articles » PMID: 39144495

Tape-assisted Fabrication Method for Constructing PDMS Membrane-containing Culture Devices with Cyclic Radial Stretching Stimulation

Overview
Journal R Soc Open Sci
Specialty Science
Date 2024 Aug 15
PMID 39144495
Authors
Affiliations
Soon will be listed here.
Abstract

Advanced culture systems have emerged as alternatives to animal testing and traditional cell culture methods in biomedical research. Polydimethylsiloxane (PDMS) is frequently used in creating sophisticated culture devices owing to its elastomeric properties, which allow mechanical stretching to simulate physiological movements in cell experiments. We introduce a straightforward method that uses three types of commercial tape-generic, magic and masking-to fabricate PDMS membranes with microscale thicknesses (47.2 µm for generic, 58.1 µm for magic and 89.37 µm for masking) in these devices. These membranes are shaped as the bases of culture wells and can perform cyclic radial movements controlled via a vacuum system. In experiments with A549 cells under three mechanical stimulation conditions, we analysed transcriptional regulators responsive to external mechanical stimuli. Results indicated increased nuclear yes-associated protein (YAP) and transcriptional coactivator with PDZ-binding motif (TAZ) activity in both confluent and densely packed cells under cyclically mechanical strains (Pearson's coefficient (PC) of 0.59 in confluent and 0.24 in dense cells) compared with static (PC = 0.47 in confluent and 0.13 in dense) and stretched conditions (PC = 0.55 in confluent and 0.20 in dense). This technique offers laboratories without microfabrication capabilities a viable option for exploring cellular behaviour under dynamic mechanical stimulation using PDMS membrane-equipped devices.

References
1.
Ingber D . Is it Time for Reviewer 3 to Request Human Organ Chip Experiments Instead of Animal Validation Studies?. Adv Sci (Weinh). 2020; 7(22):2002030. PMC: 7675190. DOI: 10.1002/advs.202002030. View

2.
Brusatin G, Panciera T, Gandin A, Citron A, Piccolo S . Biomaterials and engineered microenvironments to control YAP/TAZ-dependent cell behaviour. Nat Mater. 2018; 17(12):1063-1075. PMC: 6992423. DOI: 10.1038/s41563-018-0180-8. View

3.
Guo Y, Merten A, Scholer U, Yu Z, Cvetkovska J, Fatkin D . In vitro cell stretching technology (IsoStretcher) as an approach to unravel Piezo1-mediated cardiac mechanotransduction. Prog Biophys Mol Biol. 2020; 159:22-33. DOI: 10.1016/j.pbiomolbio.2020.07.003. View

4.
Guan M, Tang S, Chang H, Chen Y, Chen F, Mu Y . Development of alveolar-capillary-exchange (ACE) chip and its application for assessment of PM-induced toxicity. Ecotoxicol Environ Saf. 2021; 223:112601. PMC: 8421056. DOI: 10.1016/j.ecoenv.2021.112601. View

5.
Wu Q, Liu J, Wang X, Feng L, Wu J, Zhu X . Organ-on-a-chip: recent breakthroughs and future prospects. Biomed Eng Online. 2020; 19(1):9. PMC: 7017614. DOI: 10.1186/s12938-020-0752-0. View