» Articles » PMID: 39129811

One-Year Results of the Portico Transcatheter Aortic Heart Valve Using the Next-Generation FlexNav Delivery System

Abstract

Background: The FlexNav delivery system (DS) features a hydrophilic coating, stability layer, and integrated sheath to facilitate valve deployment in vessel diameters ≥5.0 mm.

Methods: Data were pooled from 2 concurrent prospective, multicenter, premarket studies (PORTICO IDE [n = 147] and FlexNav EU CE Mark [n = 46]) to evaluate the safety and efficacy of the FlexNav DS to deliver the Portico valve in the Global FlexNav study. The primary end point was Valve Academic Research Consortium (VARC)-2 major vascular complication rate at 30 days. These outcomes were compared with those of the commercially available valve arm from the PORTICO IDE study.

Results: The Global FlexNav study enrolled 193 high- or extreme-risk subjects for sugery. The mean age was 84.8 years, and 59.6% were women, with a mean Society of Thoracic Surgeons score of 5.2%. At 1 year, the rate of all-cause mortality was 5.2%, disabling stroke 2.1%, and mild or less paravalvular leak 99.4%. The mean aortic gradient was maintained at 7.4 ± 4.3 mm Hg through 1 year. At 1 year, 96.8% of subjects were classified as New York Heart Association class I or II. A pacemaker was implanted in 15.4% of subjects at 30 days and 18.4% at 1 year. The results of the Portico valve in the Global FlexNav study are comparable with the results from the commercially available valve arm in the PORTICO IDE study.

Conclusion: The FlexNav DS was shown to be safe for the delivery of the Portico valve, which demonstrated sustained treatment benefits at 1 year with low rates of all-cause mortality or disabling stroke, improved heart failure symptoms, and excellent valve performance.

Citing Articles

Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience.

Yildirim A, Genc O, Pacaci E, Sen O, Kurt I J Clin Med. 2023; 12(16).

PMID: 37629415 PMC: 10455755. DOI: 10.3390/jcm12165373.

References
1.
Popma J, Adams D, Reardon M, Yakubov S, Kleiman N, Heimansohn D . Transcatheter aortic valve replacement using a self-expanding bioprosthesis in patients with severe aortic stenosis at extreme risk for surgery. J Am Coll Cardiol. 2014; 63(19):1972-81. DOI: 10.1016/j.jacc.2014.02.556. View

2.
Leon M, Smith C, Mack M, Miller D, Moses J, Svensson L . Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010; 363(17):1597-607. DOI: 10.1056/NEJMoa1008232. View

3.
Mack M, Leon M, Thourani V, Makkar R, Kodali S, Russo M . Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients. N Engl J Med. 2019; 380(18):1695-1705. DOI: 10.1056/NEJMoa1814052. View

4.
Kappetein A, Head S, Genereux P, Piazza N, Van Mieghem N, Blackstone E . Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document (VARC-2). Eur J Cardiothorac Surg. 2012; 42(5):S45-60. DOI: 10.1093/ejcts/ezs533. View

5.
Fontana G, Bedogni F, Groh M, Smith D, Chehab B, Garrett Jr H . Safety Profile of an Intra-Annular Self-Expanding Transcatheter Aortic Valve and Next-Generation Low-Profile Delivery System. JACC Cardiovasc Interv. 2020; 13(21):2467-2478. DOI: 10.1016/j.jcin.2020.06.041. View