» Articles » PMID: 39124772

Insights into Occlusal Analysis: Articulating Paper Versus Digital Devices

Overview
Journal J Clin Med
Specialty General Medicine
Date 2024 Aug 10
PMID 39124772
Authors
Affiliations
Soon will be listed here.
Abstract

As the demand for digital dentistry constantly increases, digital devices are gradually replacing conventional methods of recording occlusal contacts. The study aimed to assess the inter-rater reliability of occlusal contact point detection using 40 μm articulating paper, Medit i700, and OccluSense and to compare the distribution of occlusal contacts using the articulating paper and intraoral scanner. The study included 25 participants aged 20 to 30 (13 women and 12 men). Photographs of contact points were taken and marked in maximum intercuspal position (MIP), in protrusive and laterotrusive movements, on working and non-working sides using 40 μm articulating paper and digital devices. The Cohen's Kappa coefficient assessed the inter-rater reliability. The Wilcoxon signed-rank test was used to compare dependent groups, articulating paper, and Medit i700. The Cohen's Kappa index showed that almost perfect agreement was achieved with 40 μm articulating paper. Compared to Medit i700, the 40 μm articulating paper showed an increased mean number of contacts per tooth, except for the third molars. : The 40 μm articulating paper has detected more overall contacts than the digital devices, particularly in the posterior areas. An ideal method for registering occlusal contacts has not been established yet.

References
1.
Sharma A, Rahul G, Poduval S, Shetty K, Gupta B, Rajora V . History of materials used for recording static and dynamic occlusal contact marks: a literature review. J Clin Exp Dent. 2014; 5(1):e48-53. PMC: 3892230. DOI: 10.4317/jced.50680. View

2.
Kerstein R . Articulating paper mark misconceptions and computerized occlusal analysis technology. Dent Implantol Update. 2008; 19(6):41-6. View

3.
Cicciu M, Fiorillo L, DAmico C, Gambino D, Amantia E, Laino L . 3D Digital Impression Systems Compared with Traditional Techniques in Dentistry: A Recent Data Systematic Review. Materials (Basel). 2020; 13(8). PMC: 7215909. DOI: 10.3390/ma13081982. View

4.
Revilla-Leon M, Kois D, Kois J . A guide for maximizing the accuracy of intraoral digital scans: Part 2-Patient factors. J Esthet Restor Dent. 2023; 35(1):241-249. DOI: 10.1111/jerd.12993. View

5.
DeLong R, Ko C, Anderson G, Hodges J, Douglas W . Comparing maximum intercuspal contacts of virtual dental patients and mounted dental casts. J Prosthet Dent. 2002; 88(6):622-30. DOI: 10.1067/mpr.2002.129379. View