» Articles » PMID: 39081438

Evaluation of Soft Tissue Changes Following Orthognathic Surgery Using Virtual Surgical Planning Software

Overview
Journal Cureus
Date 2024 Jul 31
PMID 39081438
Authors
Affiliations
Soon will be listed here.
Abstract

Context: Orthognathic surgery brings about a harmonious relationship between jaws, resulting in improved facial aesthetics. It is key to analyze if satisfactory results can be attained by using virtual surgical planning for orthognathic procedures so as to recommend it for routine clinical practice.

Aims: The aims of this study were to evaluate the various soft tissue changes that take place following orthognathic surgery using three-dimensional (3D) imaging and virtual surgical planning software and quantify the accuracy of virtual surgical planning software on patients undergoing orthognathic surgery.

Settings And Design: This is an observational prospective study with a sample size of 12.

Methods And Materials: In this prospective study, 12 patients undergoing orthognathic surgery were included following the inclusion and exclusion criteria. A usual pre-surgical work-up was done and a 3D replica of the facial skeleton was formulated using the software with the DICOM data acquired from the patient i.e., CT and scans of patient's dentition. Virtual surgical planning was done and splints were manufactured according to the desired newly achieved position. Patients were operated following the virtual surgical plan guided by the computer-aided design and computer-aided manufacturing (CAD-CAM) splints. Post-operative evaluation was done. As the study is more of a descriptive study to obtain detailed knowledge of a new procedure, only one group is being studied and hence there is no statistical testing included in this study.

Results: The mean discrepancy noticed after superimposition of soft tissue points was 0.92 with a standard deviation of 0.3.

Conclusions: 3D CT virtual surgical planning is a reliable tool to achieve predictable and reliable post-operative results in orthognathic surgical cases.

References
1.
Sun Y, Luebbers H, Agbaje J, Schepers S, Vrielinck L, Lambrichts I . Accuracy of upper jaw positioning with intermediate splint fabrication after virtual planning in bimaxillary orthognathic surgery. J Craniofac Surg. 2013; 24(6):1871-6. DOI: 10.1097/SCS.0b013e31829a80d9. View

2.
Khechoyan D . Orthognathic surgery: general considerations. Semin Plast Surg. 2014; 27(3):133-6. PMC: 3805731. DOI: 10.1055/s-0033-1357109. View

3.
Li Y, Jiang Y, Zhang N, Xu R, Hu J, Zhu S . Clinical feasibility and efficacy of using virtual surgical planning in bimaxillary orthognathic surgery without intermediate splint. J Craniofac Surg. 2015; 26(2):501-5. DOI: 10.1097/SCS.0000000000001530. View

4.
Lin H, Lonic D, Lo L . 3D printing in orthognathic surgery - A literature review. J Formos Med Assoc. 2018; 117(7):547-558. DOI: 10.1016/j.jfma.2018.01.008. View

5.
Zinser M, Sailer H, Ritter L, Braumann B, Maegele M, Zoller J . A paradigm shift in orthognathic surgery? A comparison of navigation, computer-aided designed/computer-aided manufactured splints, and "classic" intermaxillary splints to surgical transfer of virtual orthognathic planning. J Oral Maxillofac Surg. 2013; 71(12):2151.e1-21. DOI: 10.1016/j.joms.2013.07.007. View