Enhancing Early Detection of Sepsis in Neonates Through Multimodal Biosignal Integration: A Study of Pulse Oximetry, Near-Infrared Spectroscopy (NIRS), and Skin Temperature Monitoring

Overview
Date 2024 Jul 27
PMID 39061763
Authors
Affiliations
Soon will be listed here.
Abstract

Sepsis continues to be challenging to diagnose due to its non-specific clinical signs and symptoms, emphasizing the importance of early detection. Our study aimed to enhance the accuracy of sepsis diagnosis by integrating multimodal monitoring technologies with conventional diagnostic methods. The research included a total of 121 newborns, with 39 cases of late-onset sepsis, 35 cases of early-onset sepsis, and 47 control subjects. Continuous monitoring of biosignals, including pulse oximetry (PO), near-infrared spectroscopy (NIRS), and skin temperature (ST), was conducted. An algorithm was then developed in Python to identify early signs of sepsis. The model demonstrated the capability to detect sepsis 6 to 48 h in advance with an accuracy rate of 87.67 ± 7.42%. Sensitivity and specificity were recorded at 76% and 90%, respectively, with NIRS and ST having the most significant impact on predictive accuracy. Despite the promising results, limitations such as sample size, data variability, and potential biases were noted. These findings highlight the critical role of non-invasive biosensing methods in conjunction with conventional biomarkers and cultures, offering a strong foundation for early sepsis detection and improved neonatal care. Further research should be conducted to validate these results across different clinical settings.

Citing Articles

Extreme Prematurity: A Case Report on the Importance of Multidisciplinary Consultations Before and After Maternity Ward Discharge.

Peta O, Dinulescu A, Prejmereanu A, Petrescu O, Pavelescu M Cureus. 2025; 16(12):e76518.

PMID: 39872582 PMC: 11771526. DOI: 10.7759/cureus.76518.


Mathematical Models for Ultrasound Elastography: Recent Advances to Improve Accuracy and Clinical Utility.

Farajpour A, Ingman W Bioengineering (Basel). 2024; 11(10).

PMID: 39451367 PMC: 11504237. DOI: 10.3390/bioengineering11100991.

References
1.
Greisen G, Hansen M, Rasmussen M, Vestager M, Hyttel-Sorensen S, Hahn G . Cerebral Oximetry in Preterm Infants-To Use or Not to Use, That Is the Question. Front Pediatr. 2022; 9:747660. PMC: 8847778. DOI: 10.3389/fped.2021.747660. View

2.
You T, Zhou Y, Liu X, Li L . Risk Factors and Clinical Characteristics of Neonatal Acute Respiratory Distress Syndrome Caused by Early Onset Sepsis. Front Pediatr. 2022; 10:847827. PMC: 8995893. DOI: 10.3389/fped.2022.847827. View

3.
Wilson B, Cowan H, Lord J, Zuege D, Zygun D . The accuracy of pulse oximetry in emergency department patients with severe sepsis and septic shock: a retrospective cohort study. BMC Emerg Med. 2010; 10:9. PMC: 2876142. DOI: 10.1186/1471-227X-10-9. View

4.