Highly Sensitive Detection of Low-concentration Sodium Chloride Solutions Based on a Gold-coated Prism in Kretschmann Setup

Overview
Journal Heliyon
Specialty Social Sciences
Date 2024 Jul 8
PMID 38975194
Authors
Affiliations
Soon will be listed here.
Abstract

A gold-coated Kretschmann setup has been constructed and explored as a surface plasmon resonance (SPR) platform, specifically tailored for the detection of low-concentration sodium chloride (NaCl) solutions. The setup employs a BK7 prism coated with a 50 nm gold layer, serving as a plasmonic layer, to induce resonance. This resonance arises from the interplay between light waves and free electrons propagating at the interface of two media. The experimental findings reveal a notable resonance angle shift of 10° when the NaCl concentration is varied from 0 to 2.5 %. Furthermore, angle interrogation provides insightful details about the sensor's response to changes in the refractive index, showcasing a commendable sensitivity of 2400°/RIU, a high level of linearity at 0.9771, and an impressive resolution of 0.217 %. The demonstrated capabilities of this sensor underscore its potential for widespread applications, particularly in the monitoring of salt concentration across diverse domains such as seawater analysis, food processing, and fermentation processes. The robust performance and precision of this proposed sensor position it as a valuable tool with promising prospects for addressing the needs of various industries dependent on accurate salt concentration measurements.

References
1.
Gong Y, Zhao T, Rao Y, Wu Y, Guo Y . A ray-transfer-matrix model for hybrid fiber Fabry-Perot sensor based on graded-index multimode fiber. Opt Express. 2010; 18(15):15844-52. DOI: 10.1364/OE.18.015844. View

2.
Maeda M, Kadokura M, Aoki R, Komatsu N, Kawakami M, Koyama Y . A Fiber-Optic Non-Invasive Swallowing Assessment Device Based on a Wearable Pressure Sensor. Sensors (Basel). 2023; 23(4). PMC: 9963261. DOI: 10.3390/s23042355. View

3.
Topor C, Puiu M, Bala C . Strategies for Surface Design in Surface Plasmon Resonance (SPR) Sensing. Biosensors (Basel). 2023; 13(4). PMC: 10136606. DOI: 10.3390/bios13040465. View

4.
Wang Y, Huang Y, Bai H, Wang G, Hu X, Kumar S . Biocompatible and Biodegradable Polymer Optical Fiber for Biomedical Application: A Review. Biosensors (Basel). 2021; 11(12). PMC: 8699361. DOI: 10.3390/bios11120472. View

5.
Das S, Devireddy R, Gartia M . Surface Plasmon Resonance (SPR) Sensor for Cancer Biomarker Detection. Biosensors (Basel). 2023; 13(3). PMC: 10046379. DOI: 10.3390/bios13030396. View