Measurement of Glomerular Filtration Rate Using 99mTc-DTPA and the Gamma Camera: a Comparison of Methods

Overview
Journal Eur J Nucl Med
Specialty Nuclear Medicine
Date 1985 Jan 1
PMID 3896814
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

A variety of methods have been proposed to estimate the glomerular filtration rate (GFR) from the renal uptake of technetium Tc 99m-DTPA using a gamma camera. To compare alternative methods, we calculated the GFR in several different ways from measurements in 33 patients and compared the results with an independent GFR measurement based on eight-point plasma clearance of ytterbium Yb 169-DTPA. The best agreement was obtained using an algorithm that has not been described previously, in which correction was made for overlap of the kidneys by the liver and spleen. The correlation coefficient was 0.958, and the residual standard deviation was 12.1 ml/min. This method required a single 20-min blood sample as well as the camera data. The best method not requiring a blood sample was significantly less accurate, with a correlation coefficient of 0.837 and a residual standard deviation of 23.1 ml/min. The accuracy of these methods was comparable to that reported for creatinine clearance, the most commonly used estimate of the GFR in current clinical practice.

Citing Articles

Role of preoperative MR volumetry in patients with renal cell carcinoma for prediction of postoperative renal function after radical nephrectomy and nephron sparing surgery.

Lal H, Singh P, Yadav P, Singh A, Singh U, Sureka S Int Braz J Urol. 2020; 46(2):234-241.

PMID: 32022512 PMC: 7025851. DOI: 10.1590/S1677-5538.IBJU.2019.0217.


Comparison of Glomerular Filtration Rate Measurement Methods between Radionuclide in vivo Scintigraphic Gates' and Plasma Sampling.

Hussein M, Younis J, Moustafa H, Elantably I Open Access Maced J Med Sci. 2019; 7(17):2734-2738.

PMID: 31844429 PMC: 6901866. DOI: 10.3889/oamjms.2019.794.


A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods.

Jha A World J Nucl Med. 2015; 14(2):116-24.

PMID: 26097422 PMC: 4455167. DOI: 10.4103/1450-1147.154231.


Comparison of glomerular filtration rate measured by plasma sample technique, Cockroft Gault method and Gates' method in voluntary kidney donors and renal transplant recipients.

Hephzibah J, Shanthly N, Oommen R Indian J Nucl Med. 2013; 28(3):144-51.

PMID: 24250022 PMC: 3822413. DOI: 10.4103/0972-3919.119544.


Comparative assessment of techniques for estimation of glomerular filtration rate with 99mTc-DTPA.

Fawdry R, Gruenewald S, Collins L, Roberts A Eur J Nucl Med. 1985; 11(1):7-12.

PMID: 3899658 DOI: 10.1007/BF00440953.


References
1.
Brodkey M, SCHLEGEL J, DeRouen T . Determination of renal plasma flow using the gamma scintillation camera. Invest Urol. 1977; 14(6):417-20. View

2.
Smith H, GOLDRING W, CHASIS H . THE MEASUREMENT OF THE TUBULAR EXCRETORY MASS, EFFECTIVE BLOOD FLOW AND FILTRATION RATE IN THE NORMAL HUMAN KIDNEY. J Clin Invest. 1938; 17(3):263-78. PMC: 424984. DOI: 10.1172/JCI100950. View

3.
Piepsz A, Ham H, Dobbeleir A, Erbsmann F . Comments on Tc-99m DTPA scintillation camera renography. J Nucl Med. 1977; 18(10):1041-2. View

4.
Carlsen J, Moller M, Lund J, TRAP-JENSEN J . Comparison of four commercial Tc-99m(Sn)DTPA preparations used for the measurement of glomerular filtration rate: concise communication. J Nucl Med. 1980; 21(2):126-9. View

5.
Thompson Jr I, Boineau F, EVANS B, SCHLEGEL J . The renal quantitative scintillation camera study for determination of renal function. J Urol. 1983; 129(3):461-5. DOI: 10.1016/s0022-5347(17)52180-1. View