» Articles » PMID: 38946925

Stem Alignment With the Tapered Wedge Cementless Stem "Accolade II" Does Not Affect Bone Mineral Density Over 5 Years After Total Hip Arthroplasty

Overview
Publisher Elsevier
Date 2024 Jul 1
PMID 38946925
Authors
Affiliations
Soon will be listed here.
Abstract

Background: This study aimed to investigate the relationship between 3-dimensional (3D) alignment and postoperative bone mineral density (BMD) changes with Accolade II tapered wedge stems, which have a different proximal shape from other tapered wedge stems, up to 5 years after primary total hip arthroplasty.

Methods: We retrospectively analyzed the hips of 89 patients who underwent total hip arthroplasty using the second-generation proximally coated cementless stem (Accolade II; Stryker Orthopedics, Mahwah, NJ) at our institution from 2014 to 2018 over a 5-year follow-up. We evaluated the relationship between stem alignment, measured using 3D-templating software, and BMD changes in the 7 Gruen zones and compared the data with those from a former study using other short taper-wedge stems.

Results: BMDs in zones 1 and 7 continued to decrease gradually every year after surgery, and BMD in zone 7 showed the largest decrease (21%) from baseline over 5 years. No correlation was found between stem alignment (varus/valgus, flexion/extension, and anteversion/retroversion) and changes in BMD in each zone over 5 years.

Conclusions: Our data showed no correlation between 3D stem alignment and changes in BMD in each Gruen zone over 5 years. This suggests that the Accolade II stem may fit better into any shape of the proximal medullary canal because of its unique characteristics.

Citing Articles

The medullary cavity morphology of the proximal femur influences the fixation pattern of the rectangular tapered short stem in total hip arthroplasty.

Onoi Y, Hayashi S, Fujishiro T, Kuroda Y, Nakano N, Hiranaka T Arch Orthop Trauma Surg. 2024; 144(8):3857-3864.

PMID: 39198309 DOI: 10.1007/s00402-024-05500-5.

References
1.
Sevil-Kilimci F, Kara M . Canal Flare Index in the Canine Femur Is Influenced by the Measurement Method. Vet Comp Orthop Traumatol. 2020; 33(3):198-204. DOI: 10.1055/s-0040-1701501. View

2.
Kolisek F, Chughtai M, Mistry J, Elmallah R, Jaggard C, Malkani A . Outcomes of Second-Generation Tapered Wedge Femoral Stem. Surg Technol Int. 2016; 28:275-9. View

3.
Bieger R, Ignatius A, Reichel H, Durselen L . Biomechanics of a short stem: In vitro primary stability and stress shielding of a conservative cementless hip stem. J Orthop Res. 2013; 31(8):1180-6. DOI: 10.1002/jor.22349. View

4.
Issa K, Pivec R, Wuestemann T, Tatevossian T, Nevelos J, Mont M . Radiographic fit and fill analysis of a new second-generation proximally coated cementless stem compared to its predicate design. J Arthroplasty. 2013; 29(1):192-8. DOI: 10.1016/j.arth.2013.04.029. View

5.
Sayyidmousavi A, Bougherara H . Investigation of stress shielding around the Stryker Omnifit and Exeter periprosthetic hip implants using an irreversible thermodynamic-based model. J Biomed Mater Res B Appl Biomater. 2011; 100(5):1416-24. DOI: 10.1002/jbm.b.32500. View