The Feasibility of Visualizing and Quantifying Muscle Changes in Postoperative Oral Cancer Patients Using Quantitative Muscle Ultrasound (QMUS)

Overview
Journal J Ultrasound
Publisher Springer
Specialty Radiology
Date 2024 Jun 19
PMID 38896395
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Quantitative muscle ultrasound (QMUS) is a patient friendly tool for examining orofacial muscles. Resection of tissue can have an effect on the architecture and function of these muscles. The aim of this study is to investigate the feasibility of visualizing and quantifying muscle changes in postoperative oral cancer patients and to relate the findings to tumor and patient characteristics.

Methods: Adult patients with a resected first primary pT1 or T2 oral squamous cell carcinoma, at least one year post operatively, where included. Ultrasound data were collected of the geniohyoid muscle, digastric muscles, masseter muscle, transverse muscle and genioglossus muscle. Ultrasound images were labeled as clearly visible, questionable or unclear. Of the clear muscles, echogenicity and muscle thickness were measured.

Results: 37 patients were included. The masseter muscle was clearly visible in all ultrasound images, both intrinsic tongue muscles had the lowest visibility (45.9%). There was a significant correlation between visibility and tumor localization for the genioglossus (p = 0.029). Age correlated with the visibility of the genioglossus muscle, BMI with the genioglossus and transverse muscles. Echogenicity and muscle thickness of the clearly identified muscles did not differ from normative values.

Conclusion: QMUS of orofacial muscles is feasible in postoperative oral cancer patients with relatively small tumor sizes. Tongue resections negatively affected the visibility of the two intrinsic tongue muscles. These preliminary results for particular muscles indicate that the use of ultrasound might be promising in oral cancer patients to help determine targeted goals in post-operative rehabilitation.

References
1.
van Zuijlen P, Angeles A, Suijker M, Kreis R, Middelkoop E . Reliability and accuracy of techniques for surface area measurements of wounds and scars. Int J Low Extrem Wounds. 2005; 3(1):7-11. DOI: 10.1177/1534734604263200. View

1.
Zharkova N . Using ultrasound to quantify tongue shape and movement characteristics. Cleft Palate Craniofac J. 2011; 50(1):76-81. DOI: 10.1597/11-196. View

2.
van den Engel-Hoek L, Lagarde M, van Alfen N . Ultrasound of oral and masticatory muscles: Why every neuromuscular swallow team should have an ultrasound machine. Clin Anat. 2016; 30(2):183-193. DOI: 10.1002/ca.22818. View

3.
Chang P, Chen Y, Chang K, Wu W, Ozcakar L . Ultrasound measurements of superficial and deep masticatory muscles in various postures: reliability and influencers. Sci Rep. 2020; 10(1):14357. PMC: 7463001. DOI: 10.1038/s41598-020-71378-z. View

4.
Akgul Y, Kambhamettu C, Stone M . Automatic extraction and tracking of the tongue contours. IEEE Trans Med Imaging. 2000; 18(10):1035-45. DOI: 10.1109/42.811315. View