» Articles » PMID: 38851833

Three-dimensional Finite Element Analysis of the Optimal Mechanical Design for Maximum Inward Movement of the Anterior Teeth with Clear Aligners

Overview
Journal Sci Rep
Specialty Science
Date 2024 Jun 8
PMID 38851833
Authors
Affiliations
Soon will be listed here.
Abstract

This study aims to refine clinical designs within clear aligner therapy, exploring the appropriate ratio of anterior tooth retraction to intrusion under maximum anchorage. Using a three-dimensional finite element model and evaluating 19 load scenarios with first premolar extraction, the research identifies the optimal force angle for anterior tooth retraction as 45 to 55°. For clinical planning, it is recommended to design a retraction of 0.19 mm combined with an intrusion of 0.16 mm to achieve anterior tooth retraction. This investigation is crucial for enhancing understanding of biomechanical principles in clear aligner orthodontics, offering significant insights for effective treatments.

Citing Articles

Comparison of orthodontic clear aligners and fixed appliances for anterior teeth retraction using finite element analysis.

Thimmaiah C, Tomer G, Devanna R, Sharma A, Sharma T, Majumdar A Bioinformation. 2025; 20(9):1187-1190.

PMID: 39917246 PMC: 11795490. DOI: 10.6026/9732063002001187.


Modified titanium post with polished sidewalls and prefabricated shoulders can effectively preserve the teeth with subgingival defects.

Cui G, Zhang J, Cui B Sci Rep. 2025; 15(1):2864.

PMID: 39843502 PMC: 11754749. DOI: 10.1038/s41598-025-86722-4.


Using the appropriate modulus of elasticity of periodontal ligament matters in stress analysis of human first premolar tooth and periodontium structures.

Dhammayannarangsi P, Na Lampang S, Tompkins K, Everts V, Osathanon T, Limjeerajarus C Sci Rep. 2025; 15(1):1549.

PMID: 39789049 PMC: 11718098. DOI: 10.1038/s41598-025-85578-y.

References
1.
Gao J, Guo D, Zhang X, Cheng Y, Zhang H, Xu Y . Biomechanical effects of different staging and attachment designs in maxillary molar distalization with clear aligner: a finite element study. Prog Orthod. 2023; 24(1):43. PMC: 10694119. DOI: 10.1186/s40510-023-00493-0. View

2.
Li Y, Xiao S, Jin Y, Zhu C, Li R, Zheng Y . Stress and movement trend of lower incisors with different IMPA intruded by clear aligner: a three-dimensional finite element analysis. Prog Orthod. 2023; 24(1):5. PMC: 9922685. DOI: 10.1186/s40510-023-00454-7. View

3.
Liu L, Zhan Q, Zhou J, Kuang Q, Yan X, Zhang X . Effectiveness of an anterior mini-screw in achieving incisor intrusion and palatal root torque for anterior retraction with clear aligners. Angle Orthod. 2021; 91(6):794-803. PMC: 8549549. DOI: 10.2319/120420-982.1. View

4.
Will L . Orthodontic Tooth Movement: A Historic Prospective. Front Oral Biol. 2015; 18:46-55. DOI: 10.1159/000351899. View

5.
Trivedi S . Finite element analysis: A boon to dentistry. J Oral Biol Craniofac Res. 2015; 4(3):200-3. PMC: 4306993. DOI: 10.1016/j.jobcr.2014.11.008. View