» Articles » PMID: 38846144

Diagnosis of Hemidiaphragm Paralysis: Refine Ultrasound Criteria

Overview
Specialty General Medicine
Date 2024 Jun 7
PMID 38846144
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Ultrasound has demonstrated its interest in the analysis of diaphragm function in patients with respiratory failure. The criteria used to diagnose hemidiaphragm paralysis are not well defined.

Methods: The aim of this observational retrospective study was to describe the ultrasound findings in 103 patients with diaphragm paralysis, previously diagnosed by conventional methods after various circumstances such as trauma or surgery. The ultrasound study included the recording of excursions of both diaphragmatic domes and the measurement of inspiratory thickening.

Results: On paralyzed hemidiaphragm, thickening was less than 20% in all patients during deep inspiration. Thinning was recorded in 53% of cases. In some cases, the recording of the thickening could be difficult. The study of motion during voluntary sniffing reported a paradoxical excursion in all but one patient. During quiet breathing, an absence of movement or a paradoxical displacement was observed. During deep inspiration, a paradoxical motion at the beginning of inspiration followed by a reestablishment of movement in the cranio-caudal direction was seen in 82% of cases. In some patients, there was a lack of movement followed, after an average delay of 0.4 s, by a cranio-caudal excursion. Finally, in 4 patients no displacement was recorded. Evidence of hyperactivity (increased inspiratory thickening and excursion) of contralateral non-paralyzed hemidiaphragm was observed.

Conclusion: To accurately detect hemidiaphragm paralysis, it would be interesting to combine the ultrasound study of diaphragm excursion and thickening. The different profiles reported by our study must be known to avoid misinterpretation.

Citing Articles

Ultrasound analysis of hemidiaphragm function in case of pleural effusion.

Boussuges M, Bregeon F, DJourno X, Boussuges A Front Med (Lausanne). 2025; 11:1532214.

PMID: 39895818 PMC: 11782014. DOI: 10.3389/fmed.2024.1532214.


A study of machine learning to predict NRDS severity based on lung ultrasound score and clinical indicators.

Huang C, Ha X, Cui Y, Zhang H Front Med (Lausanne). 2024; 11:1481830.

PMID: 39554502 PMC: 11568467. DOI: 10.3389/fmed.2024.1481830.


Early diaphragm dysfunction assessed by ultrasonography after cardiac surgery: a retrospective cohort study.

Huai H, Ge M, Zhao Z, Xiong P, Hong W, Jiang Z Front Cardiovasc Med. 2024; 11:1457412.

PMID: 39444548 PMC: 11496164. DOI: 10.3389/fcvm.2024.1457412.

References
1.
LoMauro A, Aliverti A, Perchiazzi G, Frykholm P . Physiological changes and compensatory mechanisms by the action of respiratory muscles in a porcine model of phrenic nerve injury. J Appl Physiol (1985). 2021; 130(3):813-826. DOI: 10.1152/japplphysiol.00781.2020. View

2.
Jammes Y, Budin-Poirier C, Bregeon F . Electromyographic tools to assess hemidiaphragm paralysis. Clin Physiol Funct Imaging. 2010; 30(2):107-15. DOI: 10.1111/j.1475-097X.2009.00911.x. View

3.
Haaksma M, Smit J, Boussuges A, Demoule A, Dres M, Ferrari G . EXpert consensus On Diaphragm UltraSonography in the critically ill (EXODUS): a Delphi consensus statement on the measurement of diaphragm ultrasound-derived parameters in a critical care setting. Crit Care. 2022; 26(1):99. PMC: 8991486. DOI: 10.1186/s13054-022-03975-5. View

4.
Hunt A, Stuart C, Gergen A, Bang T, Reihman A, Helmkamp L . Long-Term Patient-Reported Symptom Improvement and Quality of Life after Transthoracic Diaphragm Plication in Adults. J Am Coll Surg. 2023; 237(3):533-544. DOI: 10.1097/XCS.0000000000000762. View

5.
Miller M, Hankinson J, Brusasco V, Burgos F, Casaburi R, Coates A . Standardisation of spirometry. Eur Respir J. 2005; 26(2):319-38. DOI: 10.1183/09031936.05.00034805. View