Abstract

Purpose Of Review: This review explores the epidemiology, clinical traits, and diagnosis of Transcatheter Aortic Valve Replacement-Associated Infective Endocarditis (TAVR-IE) and mitral transcatheter edge-to-edge repair infective endocarditis (TEER-IE), focusing on a multimodal imaging approach. It addresses the rising prevalence of TAVR and TEER, emphasizing the need to understand long-term complications and clinical consequences, which poses significant challenges despite advancements in valve technology.

Recent Findings: Studies report a variable incidence of TAVR-IE and TEER-IE influenced by diverse patient risk profiles and procedural factors. Younger age, male gender, and certain comorbidities emerge as patient-related risk factors. Procedure-related factors include intervention location, valve type, and technical aspects. Microbiologically, Staphylococcus aureus, Viridans Group Streptococcus, and Enterococcus are frequently encountered pathogens. TAVR-IE and TEER-IE diagnosis involves a multimodal imaging approach due to limitations in echocardiography. Blood cultures and imaging aid identification, with Fluorescence in situ hybridization is showing promise. Treatment encompasses medical management with antibiotics and, when necessary, surgical intervention. The management approach requires a multidisciplinary "Endocarditis Team." This review underscores the need for continued research to refine risk prediction, enhance diagnostic accuracy, and optimize management strategies for TAVR-IE, considering the evolving landscape of transcatheter interventions.

References
1.
Leon M, Smith C, Mack M, Miller D, Moses J, Svensson L . Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010; 363(17):1597-607. DOI: 10.1056/NEJMoa1008232. View

2.
Mack M, Leon M, Thourani V, Makkar R, Kodali S, Russo M . Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients. N Engl J Med. 2019; 380(18):1695-1705. DOI: 10.1056/NEJMoa1814052. View

3.
Popma J, Adams D, Reardon M, Yakubov S, Kleiman N, Heimansohn D . Transcatheter aortic valve replacement using a self-expanding bioprosthesis in patients with severe aortic stenosis at extreme risk for surgery. J Am Coll Cardiol. 2014; 63(19):1972-81. DOI: 10.1016/j.jacc.2014.02.556. View

4.
Reardon M, Van Mieghem N, Popma J, Kleiman N, Sondergaard L, Mumtaz M . Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients. N Engl J Med. 2017; 376(14):1321-1331. DOI: 10.1056/NEJMoa1700456. View

5.
Nishimura R, Otto C, Bonow R, Carabello B, Erwin 3rd J, Fleisher L . 2017 AHA/ACC Focused Update of the 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. Circulation. 2017; 135(25):e1159-e1195. DOI: 10.1161/CIR.0000000000000503. View