» Articles » PMID: 38802493

Age-related Changes of Intraocular Pressure in Dutch Belted Rabbits

Overview
Journal Sci Rep
Specialty Science
Date 2024 May 27
PMID 38802493
Authors
Affiliations
Soon will be listed here.
Abstract

This study investigated intraocular pressure (IOP) in Dutch belted rabbits using two different tonometers, rebound tonometry (TonoVet Plus; TVP) and a Tonopen (Tono-Pen AVIA Vet; TPA). Post-pubescent male Dutch belted rabbits aged 36 weeks (n = 10 animals) were used in the study. IOP measurements were conducted every 2 weeks for 22 weeks using TVP and TPA on both eyes of each rabbit. The average IOP measurements were compared by the paired Student's t-test. Pairwise Pearson's correlation coefficients and Bland-Altman statistics were used. The overall mean IOP measured with TPA was significantly higher than that with TVP (23.5 ± 4.9 vs. 21.8 ± 2.4 mmHg for the right eyes; P = 0.045, and 23.0 ± 4.7 vs. 21.5 ± 2.4 mmHg for the left eyes; P = 0.047). Both tonometers tended to show increased IOP readings with age, and positive correlations between IOP and age were observed with both TPA (r = 0.95, P < 0.001 for right eyes; r = 0.95, P < 0.001 for left eyes) and TVP (r = 0.91, P < 0.001 for right eyes; r = 0.64, P = 0.024 for left eyes). The average bias calculated by subtracting TPA from TVP was - 1.60 (95% confidence intervals - 1.927, - 1.281) mmHg. IOP in post-pubescent Dutch belted rabbits tended to increase with age throughout the 22 week study.

References
1.
Sheng Lim K, Wickremasinghe S, Cordeiro M, Bunce C, Khaw P . Accuracy of intraocular pressure measurements in new zealand white rabbits. Invest Ophthalmol Vis Sci. 2005; 46(7):2419-23. DOI: 10.1167/iovs.04-0610. View

2.
Hays C, Okafor K, Fan S, High R, Singh D, Toris C . Consequences of Puberty on Efficacy of Intraocular Pressure-Lowering Drugs in Male Dutch-Belted Rabbits. J Ocul Pharmacol Ther. 2017; 34(1-2):76-84. PMC: 6016864. DOI: 10.1089/jop.2016.0168. View

3.
Leske M, Connell A, Wu S, Hyman L, Schachat A . Distribution of intraocular pressure. The Barbados Eye Study. Arch Ophthalmol. 1997; 115(8):1051-7. DOI: 10.1001/archopht.1997.01100160221012. View

4.
Cronemberger S, Veloso A . Comparison of Tono-Pen Avia and Handheld Applanation Tonometry in Primary Congenital Glaucoma. J Glaucoma. 2021; 30(5):e227-e230. DOI: 10.1097/IJG.0000000000001820. View

5.
Rowland J, Potter D, Reiter R . Circadian rhythm in intraocular pressure: a rabbit model. Curr Eye Res. 1981; 1(3):169-73. DOI: 10.3109/02713688109001822. View