» Articles » PMID: 38799807

Intentional Oversizing of Valve in Transcatheter Aortic Valve Replacement: Is Bigger Better? A Large, Single-Center Experience

Overview
Journal Struct Heart
Publisher Elsevier
Date 2024 May 27
PMID 38799807
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The current clinical practice standard is 10% to 20% oversizing of self-expanding valves in transcatheter aortic valve replacement. We aimed to determine whether >20% oversizing of self-expanding valves (Medtronic Evolut) would lead to better valve performance with similar or better outcomes.

Methods: From October 2011 to December 2016, we approached all transcatheter aortic valve replacement patients with a conscious attempt at large oversizing (>20%). The most common valve used, excluding those used in valve-in-valve patients, was the 29-mm Evolut R (29%). We used a retrospective chart review to compare moderate oversizing (group 1; 10% to 20%) with large oversizing (group 2; >20%).

Results: Of 556 patients, 45% were male; the overall mean Society of Thoracic Surgeons risk score was 5.8 ± 3.8. Eighty-five (15%) patients needed a pacemaker, and 21 (3.8%) developed significant paravalvular leak. Mean oversizing was 20.3% ± 6.0%, with 41.4% of patients included in group 1 and 54.5% in group 2. Incidences of complications in group 2 vs. group 1 were as follows: a) paravalvular leak (2.0 vs. 6.1%; odds ratio = 0.31, = 0.01), b) pacemaker (15 vs. 14%), c) gastrointestinal bleed (n = 4 vs. 0; 1.3 vs. 0.0%; = 0.03), d) annular dissection (n = 1 vs. 0; 0.3 vs. 0%; = 0.29), e) mortality (n = 5 vs. 4; 1.6 vs. 1.7%). Incidence of paravalvular leak was higher in those who died than survivors (13 vs. 1.3%; ≤ 0.0001).

Conclusions: These data suggest that, in current self-expanding valves, >20% oversizing delivers a significantly lower prevalence of paravalvular leak without an increase in other complications. Since paravalvular leak is associated with increased mortality, >20% oversizing may represent a superior prosthesis choice.

Citing Articles

Inflow-to-Outflow Stent Frame Expansion, Ellipticity, and Decoupling in Evolut TAVR: Implications for Mid-term Hemodynamic Performance.

Puri R, Spencer J, Tchetche D, Van Mieghem N, Forrest J, Reardon M J Soc Cardiovasc Angiogr Interv. 2025; 4(1):102448.

PMID: 40061419 PMC: 11887556. DOI: 10.1016/j.jscai.2024.102448.

References
1.
Lange R, Bleiziffer S, Piazza N, Mazzitelli D, Hutter A, Tassani-Prell P . Incidence and treatment of procedural cardiovascular complications associated with trans-arterial and trans-apical interventional aortic valve implantation in 412 consecutive patients. Eur J Cardiothorac Surg. 2011; 40(5):1105-13. DOI: 10.1016/j.ejcts.2011.03.022. View

2.
Schroeter T, Linke A, Haensig M, Merk D, Borger M, Mohr F . Predictors of permanent pacemaker implantation after Medtronic CoreValve bioprosthesis implantation. Europace. 2012; 14(12):1759-63. DOI: 10.1093/europace/eus191. View

3.
Kappetein A, Head S, Genereux P, Piazza N, Van Mieghem N, Blackstone E . Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. J Am Coll Cardiol. 2012; 60(15):1438-54. DOI: 10.1016/j.jacc.2012.09.001. View

4.
Holmes Jr D, Mack M, Kaul S, Agnihotri A, Alexander K, Bailey S . 2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement. J Am Coll Cardiol. 2012; 59(13):1200-54. DOI: 10.1016/j.jacc.2012.01.001. View

5.
Abdel-Wahab M, Mehilli J, Frerker C, Neumann F, Kurz T, Tolg R . Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial. JAMA. 2014; 311(15):1503-14. DOI: 10.1001/jama.2014.3316. View