» Articles » PMID: 38795646

Bio(sensors) Based on Molecularly Imprinted Polymers and Silica Materials Used for Food Safety and Biomedical Analysis: Recent Trends and Future Prospects

Overview
Journal Talanta
Publisher Elsevier
Specialty Chemistry
Date 2024 May 25
PMID 38795646
Authors
Affiliations
Soon will be listed here.
Abstract

In recent decades, analytical techniques have increasingly focused on the precise quantification. Achieving this goal has been accomplished with conventional analytical approaches that typically require extensive pretreatment methods, significant reagent usage, and expensive instruments. The need for rapid, simple, and highly selective identification platforms has become increasingly pronounced. Molecularly imprinted polymer (MIP) has emerged as a promising avenue for developing advanced sensors that can potentially surpass the limitations of conventional detection methods. In recent years, the application of MIP-silica materials-based sensors has garnered significant attention owing to their distinctive characteristics. These types of probes hold a distinct advantage in their remarkable stability and durability, all of which provide a suitable sensing platform in severe environments. Moreover, the substrate composed of silica materials offers a vast surface area for binding, thereby facilitating the efficient detection of even minuscule concentrations of targets. As a result, sensors based on MIP-silica materials have the potential to be widely applied in various industries, including medical diagnosis, and food safety. In the present review, we have conducted an in-depth analysis of the latest research developments in the field of MIPs-silica materials based sensors, with a focus on succinctly summarizing and elucidating the most crucial findings. This is the first comprehensive review of integration MIPs with silica materials in electrochemical (EC) and optical probes for biomedical analysis and food safety.

Citing Articles

Curcumin-Based Molecularly Imprinted Polymer Electropolymerized on Single-Use Graphite Electrode for Dipyridamole Analysis.

Preda D, Radu G, Iorgulescu E, Cheregi M, David I Molecules. 2024; 29(19).

PMID: 39407560 PMC: 11477586. DOI: 10.3390/molecules29194630.


Evaluation of Transducer Elements Based on Different Material Configurations for Aptamer-Based Electrochemical Biosensors.

Lopez Carrasco I, Cuniberti G, Opitz J, Beshchasna N Biosensors (Basel). 2024; 14(7).

PMID: 39056617 PMC: 11274616. DOI: 10.3390/bios14070341.