Abstract

In this paper, a new sensor is proposed to efficiently gather crucial information on corrosion phenomena and their progression within steel components. Fabricated with plastic optical fibers (POF), the sensor can detect corrosion-induced physical changes in the appearance of monitoring points within the steel material. Additionally, the new sensor incorporates an innovative structure that efficiently utilizes bi-directional optical transmission in the POF, simplifying the installation procedure and reducing the total cost of the POF cables by as much as 50% when monitoring multiple points. Furthermore, an extremely compact dummy sensor with the length of 5 mm and a diameter of 2.2 mm for corrosion-depth detection was introduced, and its functionality was validated through experiments. This paper outlines the concept and fundamental structure of the proposed sensor; analyzes the results of various experiments; and discusses its effectiveness, prospects, and economic advantages.

Citing Articles

A 1 × 8 Optical Splitter Based on Polycarbonate Multicore Polymer Optical Fibers.

Lanziano L, Sherf I, Malka D Sensors (Basel). 2024; 24(15).

PMID: 39124110 PMC: 11315036. DOI: 10.3390/s24155063.

References
1.
Komary M, Komarizadehasl S, Tosic N, Segura I, Lozano-Galant J, Turmo J . Low-Cost Technologies Used in Corrosion Monitoring. Sensors (Basel). 2023; 23(3). PMC: 9920423. DOI: 10.3390/s23031309. View

2.
Hou L, Akutagawa S, Tomoshige Y, Kimura T . Experimental Investigation for Monitoring Corrosion Using Plastic Optical Fiber Sensors. Sensors (Basel). 2024; 24(3). PMC: 10857450. DOI: 10.3390/s24030885. View

3.
Liu H, Liang D, Han X, Zeng J . Long period fiber grating transverse load effect-based sensor for the omnidirectional monitoring of rebar corrosion in concrete. Appl Opt. 2013; 52(14):3246-52. DOI: 10.1364/AO.52.003246. View

4.
Kovac J, Legat A, Zajec B, Kosec T, Govekar E . Detection and characterization of stainless steel SCC by the analysis of crack related acoustic emission. Ultrasonics. 2015; 62:312-22. DOI: 10.1016/j.ultras.2015.06.005. View

5.
Dos Santos P, Jorge P, Almeida J, Coelho L . Low-Cost Interrogation System for Long-Period Fiber Gratings Applied to Remote Sensing. Sensors (Basel). 2019; 19(7). PMC: 6480325. DOI: 10.3390/s19071500. View