» Articles » PMID: 38785715

Electrochemical Impedance Spectroscopy for Ion Sensors with Interdigitated Electrodes: Capacitance Calculations, Equivalent Circuit Models and Design Optimizations

Overview
Specialty Biotechnology
Date 2024 May 24
PMID 38785715
Authors
Affiliations
Soon will be listed here.
Abstract

Electrochemical impedance spectroscopy (EIS) is becoming more and more relevant for the characterization of biosensors employing interdigitated electrodes. We compare four different sensor topologies for an exemplary use case of ion sensing to extract recommendations for the design optimizations of impedimetric biosensors. Therefore, we first extract how sensor design parameters affect the sensor capacitance using analytical calculations and finite element (FEM) simulations. Moreover, we develop equivalent circuit models for our sensor topologies and validate them using FEM simulations. As a result, the impedimetric sensor response is better understood, and sensitive and selective frequency ranges can be determined for a given sensor topology. From this, we extract design optimizations for different sensing principles.

Citing Articles

Feasibility Study of a Non-Contact Differentiation of Cannabidiol Concentrations Using Interdigital Electrodes.

Boonrat K, Jaroenkunpanit P, Wounchoum P, Jantarachote V, Chetpattananondh P, Chetpattananondh K ACS Omega. 2025; 9(52):51515-51524.

PMID: 39758664 PMC: 11696433. DOI: 10.1021/acsomega.4c08811.

References
1.
Kazemi S, Shanehsaz M, Ghaemmaghami M . Non-Faradaic electrochemical impedance spectroscopy as a reliable and facile method: Determination of the potassium ion concentration using a guanine rich aptasensor. Mater Sci Eng C Mater Biol Appl. 2015; 52:151-4. DOI: 10.1016/j.msec.2015.03.058. View

2.
Day C, Sopstad S, Ma H, Jiang C, Nathan A, Elliott S . Impedance-based sensor for potassium ions. Anal Chim Acta. 2018; 1034:39-45. DOI: 10.1016/j.aca.2018.06.044. View

3.
Ibau C, Md Arshad M, Gopinath S, Nuzaihan M N M, Fathil M, Shamsuddin S . Immunosensing prostate-specific antigen: Faradaic vs non-Faradaic electrochemical impedance spectroscopy analysis on interdigitated microelectrode device. Int J Biol Macromol. 2020; 162:1924-1936. DOI: 10.1016/j.ijbiomac.2020.08.125. View

4.
Ameer S, Ibrahim H, Yaseen M, Kulsoom F, Cinti S, Sher M . Electrochemical Impedance Spectroscopy-Based Sensing of Biofilms: A Comprehensive Review. Biosensors (Basel). 2023; 13(8). PMC: 10452506. DOI: 10.3390/bios13080777. View

5.
Wang Z, Murphy A, ORiordan A, OConnell I . Equivalent Impedance Models for Electrochemical Nanosensor-Based Integrated System Design. Sensors (Basel). 2021; 21(9). PMC: 8125801. DOI: 10.3390/s21093259. View