» Articles » PMID: 38776828

Optimization and Application of Pretreatment Method of Microplastics Detection in Municipal Solid Waste Landfills

Overview
Journal Waste Manag
Date 2024 May 22
PMID 38776828
Authors
Affiliations
Soon will be listed here.
Abstract

The landfill is one of the most important sources of microplastics (MPs). The pretreatment method is a precondition of microplastics study for the presence of complex substances in landfills. Therefore, it is essential to examine the impact of different pretreatment methods on the microplastics detection. A literature review and a comparison experiment on digestion solutions were performed to establish a comprehensive identification method for MPs in landfills. When exposed to of 30 % HO, minimal mass reduction of PE, PP and PET were 4.00 %, 3.00 % and 3.00 % respectively, and the least surface damage was observed in MPs, while exhibiting the most optimal peak value for infrared spectral characteristics. It is demonstrated that the effect of 30 % HO dissolution was superior compared to 10 % KOH and 65 % HNO. The method was subsequently utilized to investigate the distribution of MPs in a landfill. The dominant MPs were polyethylene (PE, 18.56-23.91 %), polyethylene terephthalate (PET, 8.80-18.66 %), polystyrene (PS, 10.31-18.09 %), and polypropylene (PP, 11.60-14.91 %). The comprehensive identification method of "NaCl density separation + 30 % HO digestion + NaI density separation + sampling microscope + Mirco-FTIR" is suitable for the detection of MPs in landfills.