» Articles » PMID: 38694586

Impact of Sample Type on D-Dimer Screening

Overview
Specialty General Medicine
Date 2024 May 2
PMID 38694586
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The quality of laboratory test results depends on various factors, including sample type selection. Blood samples, such as whole blood, plasma and serum are commonly used for most clinical laboratory examinations. D-dimer parameters are frequently analysed in haematology laboratories and serve as biomarkers for coagulation activation and fibrinolysis. This study aimed to assess the impact of using different sample types on the quality of D-dimer test results.

Method: An observational analytical method was used. D-dimer examination was performed using the fluorescent lateral flow immunoassay method. The study sample consisted of 26 participants aged between 18 years old and 22 years old who had no blood disorders. Whole blood and ethylenediaminetetraacetic acid (EDTA) plasma samples were used for the examination of D-dimer levels.

Results: D-dimer levels in 26 participants using whole blood samples had a mean value of 0.23 mg/L (230 ng/mL), while plasma samples yielded a mean value of 0.14 mg/L (140 ng/mL). D-dimer levels obtained from whole blood samples were higher than plasma samples but remained within the normal range of 0 mg/L-0.5 mg/L (0 ng/mL-500 ng/mL).

Conclusion: The results showed that whole blood samples were more practical than plasma samples. Nevertheless, plasma samples gave results within the normal range of D-dimer values.

References
1.
Jones A, Miller J, Jansen J, Wang H . Whole Blood for Resuscitation of Traumatic Hemorrhagic Shock in Adults. Adv Emerg Nurs J. 2021; 43(4):344-354. PMC: 8555430. DOI: 10.1097/TME.0000000000000376. View

2.
Leeman M, Choi J, Hansson S, Storm M, Nilsson L . Proteins and antibodies in serum, plasma, and whole blood-size characterization using asymmetrical flow field-flow fractionation (AF4). Anal Bioanal Chem. 2018; 410(20):4867-4873. PMC: 6061777. DOI: 10.1007/s00216-018-1127-2. View

3.
Decru B, Van Elslande J, Weemaes M, Houben E, Empsen I, Andre E . Comparison of the diagnostic performance with whole blood and plasma of four rapid antibody tests for SARS-CoV-2. Clin Chem Lab Med. 2020; 58(10):e197-e199. DOI: 10.1515/cclm-2020-0817. View

4.
Lippi G, Chance J, Church S, Dazzi P, Fontana R, Giavarina D . Preanalytical quality improvement: from dream to reality. Clin Chem Lab Med. 2011; 49(7):1113-26. DOI: 10.1515/CCLM.2011.600. View

5.
Johnson E, Schell J, Rodgers G . The D-dimer assay. Am J Hematol. 2019; 94(7):833-839. DOI: 10.1002/ajh.25482. View