Stress & Strain in Mechanically Nonuniform Alveoli Using Clinical Input Variables: a Simple Conceptual Model

Overview
Journal Crit Care
Specialty Critical Care
Date 2024 Apr 28
PMID 38679712
Authors
Affiliations
Soon will be listed here.
Abstract

Clinicians currently monitor pressure and volume at the airway opening, assuming that these observations relate closely to stresses and strains at the micro level. Indeed, this assumption forms the basis of current approaches to lung protective ventilation. Nonetheless, although the airway pressure applied under static conditions may be the same everywhere in healthy lungs, the stresses within a mechanically non-uniform ARDS lung are not. Estimating actual tissue stresses and strains that occur in a mechanically non-uniform environment must account for factors beyond the measurements from the ventilator circuit of airway pressures, tidal volume, and total mechanical power. A first conceptual step for the clinician to better define the VILI hazard requires consideration of lung unit tension, stress focusing, and intracycle power concentration. With reasonable approximations, better understanding of the value and limitations of presently used general guidelines for lung protection may eventually be developed from clinical inputs measured by the caregiver. The primary purpose of the present thought exercise is to extend our published model of a uniform, spherical lung unit to characterize the amplifications of stress (tension) and strain (area change) that occur under static conditions at interface boundaries between a sphere's surface segments having differing compliances. Together with measurable ventilating power, these are incorporated into our perspective of VILI risk. This conceptual exercise brings to light how variables that are seldom considered by the clinician but are both recognizable and measurable might help gauge the hazard for VILI of applied pressure and power.

Citing Articles

A narrative review on the future of ARDS: evolving definitions, pathophysiology, and tailored management.

Al-Husinat L, Azzam S, Al Sharie S, Araydah M, Battaglini D, Abushehab S Crit Care. 2025; 29(1):88.

PMID: 39994815 PMC: 11852867. DOI: 10.1186/s13054-025-05291-0.


Mechanical power and VILI: modeling limits and unknowns.

Tonetti T, Marini J Intensive Care Med Exp. 2025; 13(1):1.

PMID: 39760961 PMC: 11704099. DOI: 10.1186/s40635-024-00712-w.


Editorial: Personalized therapy in ARDS, volume II.

Battaglini D, Guerin C, Rocco P Front Med (Lausanne). 2024; 11:1533593.

PMID: 39736977 PMC: 11683102. DOI: 10.3389/fmed.2024.1533593.


Mechanical power is associated with cardiac output and pulmonary blood flow in an experimental acute respiratory distress syndrome in pigs.

Zhang Y, Wittenstein J, Braune A, Theilen R, Maiello L, Benzi G Front Physiol. 2024; 15:1462954.

PMID: 39473611 PMC: 11519626. DOI: 10.3389/fphys.2024.1462954.

References
1.
Gattinoni L, Pesenti A . The concept of "baby lung". Intensive Care Med. 2005; 31(6):776-84. DOI: 10.1007/s00134-005-2627-z. View

2.
Mead J, Takishima T, Leith D . Stress distribution in lungs: a model of pulmonary elasticity. J Appl Physiol. 1970; 28(5):596-608. DOI: 10.1152/jappl.1970.28.5.596. View

3.
Shelmerdine S, Barber J, George C . Applications of Laplace's law in clinical medicine: a radiological pictorial review. Br J Hosp Med (Lond). 2013; 74(8):451-6. DOI: 10.12968/hmed.2013.74.8.451. View

4.
Protti A, Cressoni M, Santini A, Langer T, Mietto C, Febres D . Lung stress and strain during mechanical ventilation: any safe threshold?. Am J Respir Crit Care Med. 2011; 183(10):1354-62. DOI: 10.1164/rccm.201010-1757OC. View

5.
Marini J, Thornton L, Rocco P, Gattinoni L, Crooke P . Practical assessment of risk of VILI from ventilating power: a conceptual model. Crit Care. 2023; 27(1):157. PMC: 10120146. DOI: 10.1186/s13054-023-04406-9. View