Suitability and Trueness of the Removable Partial Denture Framework Fabricating by Polyether Ether Ketone with CAD-CAM Technology

Overview
Publisher MDPI
Date 2024 Apr 27
PMID 38675038
Authors
Affiliations
Soon will be listed here.
Abstract

The object of the study was to evaluate the suitability and trueness of the removable partial denture (RPD) framework fabricated by polyether ether ketone (PEEK) with the CAD-CAM technology in vitro. Four different types of dentition defects were selected. In each type, five PEEK RPD frameworks were fabricated by the CAD-CAM technology, while five Co-Cr RPD frameworks were made by traditional casting. The suitability of the framework was evaluated by silicone rubber film slice measurement and the three-dimensional image overlay method. The trueness of the PEEK framework was detected by the three-dimensional image overlay method. Data were statistically analyzed with the use of an independent samples -test (α = 0.05). The suitability values by silicone rubber film slice measurement of the PEEK group were lower than those of the Co-Cr group in four types, with the differences indicating statistical significance ( < 0.05) in type one, type two, and type four. The suitability values using the three-dimensional image overlay method showed no statistical differences ( > 0.05) between the two groups in four types. The trueness values of the PEEK group were within the allowable range of clinical error. The suitability and trueness of the PEEK RPD framework fabricated by CAD-CAM technology met the requirements of the clinical prosthesis.

Citing Articles

Evaluation of Fitting Accuracy of Light- and Auto-Polymerizing Reline Materials Using Three-Dimensional Measurement Techniques.

Utsumi M, Murakami N, Yamazaki T, Hirata A, Komine K, Li B Polymers (Basel). 2025; 17(2).

PMID: 39861273 PMC: 11769256. DOI: 10.3390/polym17020201.

References
1.
Lee J, Park J, Park E, Heo S, Koak J, Kim S . Accuracy of a digital removable partial denture fabricated by casting a rapid prototyped pattern: A clinical study. J Prosthet Dent. 2017; 118(4):468-474. DOI: 10.1016/j.prosdent.2016.12.007. View

2.
Peng P, Hsu C, Huang H, Chao J, Lee W . Trueness of removable partial denture frameworks additively manufactured with selective laser melting. J Prosthet Dent. 2020; 127(1):122-127. DOI: 10.1016/j.prosdent.2020.06.035. View

3.
Almufleh B, Arellanob A, Tamimi F . Patient-reported outcomes and framework fit accuracy of removable partial dentures fabricated using digital techniques: A systematic review and meta-analysis. J Prosthodont. 2023; 33(7):626-636. DOI: 10.1111/jopr.13786. View

4.
Trivedi S . Finite element analysis: A boon to dentistry. J Oral Biol Craniofac Res. 2015; 4(3):200-3. PMC: 4306993. DOI: 10.1016/j.jobcr.2014.11.008. View

5.
Sadek S . Comparative Study Clarifying the Usage of PEEK as Suitable Material to Be Used as Partial Denture Attachment and Framework. Open Access Maced J Med Sci. 2019; 7(7):1193-1197. PMC: 6490496. DOI: 10.3889/oamjms.2019.287. View