» Articles » PMID: 38675020

A New Approach to Implant Stability Using a Flexible Synthetic Silicate-Additive Beta-Tricalcium Phosphate-Poly(D,L-lactide--caprolactone) Bone Graft: An In Vitro Study

Overview
Publisher MDPI
Date 2024 Apr 27
PMID 38675020
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of this study was to evaluate the use of a flexible synthetic polymer bone graft to provide implant stability during implant placement in a dense cortical bone model. In the control group (Group 1), sockets were prepared on polyurethane blocks according to the standard implant socket drilling protocol; both oversizing and deepening were applied in Group 2; and only oversizing was applied in Group 3. In Groups 2 and 3, flexible synthetic polymer bone grafts were placed in the sockets prior to implant placement. The implants were placed at the bone level in all groups. The highest torque value obtained was recorded as the insertion torque. In this study, 75 implant sites were included across three groups. The torque values of the implants in the control group were significantly higher than those of the implants with the oversized and deepened sockets and the oversized-only sockets ( < 0.05; < 0.01). The torque values of the implants with the oversized and deepened sockets were significantly higher than those of the implants with the oversized-only sockets ( < 0.01). In this study, a flexible synthetic polymer bone graft was shown to be effective in achieving implant stability in the management of implants where there has been a loss of primary stability.

References
1.
Javed F, Ahmed H, Crespi R, Romanos G . Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation. Interv Med Appl Sci. 2014; 5(4):162-7. PMC: 3873594. DOI: 10.1556/IMAS.5.2013.4.3. View

2.
Ulery B, Nair L, Laurencin C . Biomedical Applications of Biodegradable Polymers. J Polym Sci B Polym Phys. 2011; 49(12):832-864. PMC: 3136871. DOI: 10.1002/polb.22259. View

3.
Linetskiy I, Demenko V, Linetska L, Yefremov O . Impact of annual bone loss and different bone quality on dental implant success - A finite element study. Comput Biol Med. 2017; 91:318-325. DOI: 10.1016/j.compbiomed.2017.09.016. View

4.
Aldahlawi S, Demeter A, Irinakis T . The effect of implant placement torque on crestal bone remodeling after 1 year of loading. Clin Cosmet Investig Dent. 2018; 10:203-209. PMC: 6183656. DOI: 10.2147/CCIDE.S174895. View

5.
Coathup M, Samizadeh S, Fang Y, Buckland T, Hing K, Blunn G . The osteoinductivity of silicate-substituted calcium phosphate. J Bone Joint Surg Am. 2011; 93(23):2219-26. DOI: 10.2106/JBJS.I.01623. View