In Vivo Micro-computed Tomography Evaluation of Radiopaque, Polymeric Device Degradation in Normal and Inflammatory Environments

Overview
Journal Acta Biomater
Publisher Elsevier
Date 2024 Apr 22
PMID 38648912
Authors
Affiliations
Soon will be listed here.
Abstract

Polymeric biomedical implants are an important clinical tool, but degradation remains difficult to determine post-implantation. Computed tomography (CT) could be a powerful tool for device monitoring, but polymers require incorporation of radiopaque contrast agents to be distinguishable from tissue. In addition, immune response to radiopaque devices must be characterized as it modulates device function. Radiopaque devices and films were produced by incorporating 0-20 wt% TaO nanoparticles into polymers: polycaprolactone (PCL) and poly(lactide-co-glycolide) (PLGA). In vitro inflammatory responses of mouse bone marrow-derived macrophages to polymer matrix incorporating TaO nanoparticles was determined by monitoring cytokine secretion. Nanoparticle addition stimulated a slight inflammatory reaction, increasing TNFα secretion, mediated by changes in polymer matrix properties. Subsequently, devices (PLGA 50:50 + 20 wt% TaO) were implanted subcutaneously in a mouse model of chronic inflammation, that featured a sustained increase in inflammatory response local to the implant site over 12 weeks. No changes to device degradation rates or foreign body response were noted between a normal and chronically stimulated inflammatory environment. Serial CT device monitoring post-implantation provided a detailed timeline of device collapse, with no rapid, spontaneous release of nanoparticles that occluded matrix visualization. Importantly, repeat CT sessions did not ablate the immune system or alter degradation kinetics. Thus, polymer devices incorporating radiopaque nanoparticles can be used for in situ monitoring and be readily combined with other medical imaging techniques, for a dynamic view biomaterial and tissue interactions. STATEMENT OF SIGNIFICANCE: A growing number of implantable devices are in use in the clinic, exposing patients to inherent risks of implant movement, collapse, and infection. The ability to monitor implanted devices would enable faster diagnosis of failure and open the door for personalized rehabilitation therapies - both of which could vastly improve patient outcomes. Unfortunately, polymeric materials which make up most biomedical devices are not radiologically distinguishable from tissue post-implantation. The introduction of radiopaque nanoparticles into polymers allows for serial monitoring via computed tomography, without affecting device degradation. Here we demonstrate for the first time that nanoparticles do not undergo burst release from devices post-implantation and that inflammatory responses - a key determinant of device function in vivo - are also unaffected by nanoparticle addition.

Citing Articles

Material Composition and Implantation Site Affect in vivo Device Degradation Rate.

Pawelec K, Hix J, Troia A, Kiupel M, Shapiro E bioRxiv. 2024; .

PMID: 39314464 PMC: 11419000. DOI: 10.1101/2024.09.09.612079.

References
1.
Witherel C, Sao K, Brisson B, Han B, Volk S, Petrie R . Regulation of extracellular matrix assembly and structure by hybrid M1/M2 macrophages. Biomaterials. 2021; 269:120667. PMC: 7870567. DOI: 10.1016/j.biomaterials.2021.120667. View

2.
Almuttaqi H, Udalova I . Advances and challenges in targeting IRF5, a key regulator of inflammation. FEBS J. 2018; 286(9):1624-1637. PMC: 6563445. DOI: 10.1111/febs.14654. View

3.
Le Goas M, Testard F, Tache O, Debou N, Cambien B, Carrot G . How Do Surface Properties of Nanoparticles Influence Their Diffusion in the Extracellular Matrix? A Model Study in Matrigel Using Polymer-Grafted Nanoparticles. Langmuir. 2020; 36(35):10460-10470. DOI: 10.1021/acs.langmuir.0c01624. View

4.
Miyahara N, Kokubo T, Hara Y, Yamada A, Koike T, Arai Y . Evaluation of X-ray doses and their corresponding biological effects on experimental animals in cone-beam micro-CT scans (R-mCT2). Radiol Phys Technol. 2015; 9(1):60-8. PMC: 4722077. DOI: 10.1007/s12194-015-0334-1. View

5.
Riemann A, Wussling H, Loppnow H, Fu H, Reime S, Thews O . Acidosis differently modulates the inflammatory program in monocytes and macrophages. Biochim Biophys Acta. 2015; 1862(1):72-81. DOI: 10.1016/j.bbadis.2015.10.017. View