» Articles » PMID: 38638812

Synthesis and Characterization of a Nanostructure Conductive Copolymer Based on Polyaniline and Polylactic Acid As an Effective Substrate in Proteins Impedimetric Biosensing

Overview
Journal RSC Adv
Specialty Chemistry
Date 2024 Apr 19
PMID 38638812
Authors
Affiliations
Soon will be listed here.
Abstract

Despite of all the developments in DNA microarray technology, there is not sufficient knowledge about protein abundance or their function in processes such as proteolysis, phosphorylation. Therefore, there is a significant need for direct detection and quantification of proteins, especially in processes such as proteomics, drug design and disease prediction. The present work introduce the new generation of polymeric substrate based on polyaniline and, polylactic acid, which it was used for impedimetric sensor in detection of proteins in particular for bovine serum albumin (BSA). In this copolymerization, the polylactic acid--polyaniline copolymer (PLA--PANI) was synthesized to attach polylactic acid and polyaniline using epichlorohydrin as a coupling agent. The structure of synthesized compounds in all steps, were confirmed by FT-IR and, H-NMR. The thermal properties and, morphology were analyzed by DSC, TGA, and, SEM. Also the electrochemical characteristics of fabricated PLA--PANI electrode were investigated by Electrochemical Impedance Spectroscopy (EIS) and Cyclic Voltammetry (CV). The results demonstrated that morphology of the PLA--PANI is sphere shape nanoparticles with dimension less than 100 nanometer diameters and, reasonable thermal properties. PLA--PANI was used to modify a screen-printed carbon electrode (SPCE) to fabricate a BSA impedimetric sensor. In order to increase the performance of the proposed impedimetric sensor, optimization of incubation time, pH and amount of PLA--PANI were investigated. The results show that the impedimetric sensor has the highest response when the electrode surface is covered with 5 microliters of PLA--PANI, and is incubated in BSA solution with pH 6.5 for 5 min. Impedimetric results showed that the PLA--PANI has excellent properties in reducing the charge transfer resistance and increasing the electron charge transfer rate. The final impedimetric sensor exhibited good repeatability, reproducibility, and chemical stability within the linear concentration range of 0.1-20 μg L of BSA, and a detection limit of 0.05 μg L.

Citing Articles

Preparation of PLA Nanoparticles and Study of Their Influencing Factors.

Zhang X, Luo Q, Zhang F, Zhao X, Li Y, Yang N Molecules. 2024; 29(23).

PMID: 39683726 PMC: 11643530. DOI: 10.3390/molecules29235566.

References
1.
Guerrero A, Bisquert J, Garcia-Belmonte G . Impedance Spectroscopy of Metal Halide Perovskite Solar Cells from the Perspective of Equivalent Circuits. Chem Rev. 2021; 121(23):14430-14484. DOI: 10.1021/acs.chemrev.1c00214. View

2.
Zhu C, Yang G, Li H, Du D, Lin Y . Electrochemical sensors and biosensors based on nanomaterials and nanostructures. Anal Chem. 2014; 87(1):230-49. PMC: 4287168. DOI: 10.1021/ac5039863. View

3.
Ramanavicius S, Ramanavicius A . Conducting Polymers in the Design of Biosensors and Biofuel Cells. Polymers (Basel). 2020; 13(1). PMC: 7795957. DOI: 10.3390/polym13010049. View

4.
Dong J, Zhao H, Xu M, Ma Q, Ai S . A label-free electrochemical impedance immunosensor based on AuNPs/PAMAM-MWCNT-Chi nanocomposite modified glassy carbon electrode for detection of Salmonella typhimurium in milk. Food Chem. 2013; 141(3):1980-6. DOI: 10.1016/j.foodchem.2013.04.098. View

5.
Zare E, Makvandi P, Ashtari B, Rossi F, Motahari A, Perale G . Progress in Conductive Polyaniline-Based Nanocomposites for Biomedical Applications: A Review. J Med Chem. 2019; 63(1):1-22. DOI: 10.1021/acs.jmedchem.9b00803. View