» Articles » PMID: 38633075

Preserving Shape Details of Pulse Signals for Video-based Blood Pressure Estimation

Overview
Specialty Radiology
Date 2024 Apr 18
PMID 38633075
Authors
Affiliations
Soon will be listed here.
Abstract

In recent years, imaging photoplethysmograph (iPPG) pulse signals have been widely used in the research of non-contact blood pressure (BP) estimation, in which BP estimation based on pulse features is the main research direction. Pulse features are directly related to the shape of pulse signals while iPPG pulse signals are easily disturbed during the extraction process. To mitigate the impact of pulse feature distortion on BP estimation, it is necessary to eliminate interference while retaining valuable shape details in the iPPG pulse signal. Contact photoplethysmograph (cPPG) pulse signals measured at rest can be considered as the undisturbed reference signal. Transforming the iPPG pulse signal to the corresponding cPPG pulse signal is a method to ensure the effectiveness of shape details. However, achieving the required shape accuracy through direct transformation from iPPG to the corresponding cPPG pulse signals is challenging. We propose a method to mitigate this challenge by replacing the reference signal with an average cardiac cycle (ACC) signal, which can approximately represent the shape information of all cardiac cycles in a short time. A neural network using multi-scale convolution and self-attention mechanisms is developed for this transformation. Our method demonstrates a significant improvement in the maximal information coefficient (MIC) between pulse features and BP values, indicating a stronger correlation. Moreover, pulse signals transformed by our method exhibit enhanced performance in BP estimation using different model types. Experiments are conducted on a real-world database with 491 subjects in the hospital, averaging 60 years of age.

References
1.
Mukkamala R, Hahn J, Inan O, Mestha L, Kim C, Toreyin H . Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice. IEEE Trans Biomed Eng. 2015; 62(8):1879-901. PMC: 4515215. DOI: 10.1109/TBME.2015.2441951. View

2.
Jeong I, Finkelstein J . Introducing Contactless Blood Pressure Assessment Using a High Speed Video Camera. J Med Syst. 2016; 40(4):77. DOI: 10.1007/s10916-016-0439-z. View

3.
de Haan G, van Leest A . Improved motion robustness of remote-PPG by using the blood volume pulse signature. Physiol Meas. 2014; 35(9):1913-1926. DOI: 10.1088/0967-3334/35/9/1913. View

4.
Chu Y, Tang K, Hsu Y, Huang T, Wang D, Li W . Non-invasive arterial blood pressure measurement and SpO estimation using PPG signal: a deep learning framework. BMC Med Inform Decis Mak. 2023; 23(1):131. PMC: 10362790. DOI: 10.1186/s12911-023-02215-2. View

5.
Liu Z, Zhou C, Wang H, He Y . Blood pressure monitoring techniques in the natural state of multi-scenes: A review. Front Med (Lausanne). 2022; 9:851172. PMC: 9462511. DOI: 10.3389/fmed.2022.851172. View