Continuous Glucose Monitoring for Prediabetes: What Are the Best Metrics?

Overview
Specialty Endocrinology
Date 2024 Apr 17
PMID 38629784
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Continuous glucose monitoring (CGM) has transformed the care of type 1 and type 2 diabetes, and there is potential for CGM to also become influential in prediabetes identification and management. However, to date, we do not have any consensus guidelines or high-quality evidence to guide CGM goals and metrics for use in prediabetes.

Methods: We searched PubMed for all English-language articles on CGM use in nonpregnant adults with prediabetes published by November 1, 2023. We excluded any articles that included subjects with type 1 diabetes or who were known to be at risk for type 1 diabetes due to positive islet autoantibodies.

Results: Based on the limited data available, we suggest possible CGM metrics to be used for individuals with prediabetes. We also explore the role that glycemic variability (GV) plays in the transition from normoglycemia to prediabetes.

Conclusions: Glycemic variability indices beyond the standard deviation and coefficient of variation are emerging as prominent identifiers of early dysglycemia. One GV index in particular, the mean amplitude of glycemic excursion (MAGE), may play a key future role in CGM metrics for prediabetes and is highlighted in this review.

Citing Articles

Glucose Abnormalities Detected by Continuous Glucose Monitoring in Very Old Adults With and Without Diabetes.

Daya N, Fang M, Wang D, Valint A, Windham B, Coresh J Diabetes Care. 2024; 48(3):416-421.

PMID: 39705138 PMC: 11870281. DOI: 10.2337/dc24-1990.


Exploring the Continuous Glucose Monitoring in Pediatric Diabetes: Current Practices, Innovative Metrics, and Future Implications.

Chobot A, Piona C, Bombaci B, Kaminska-Jackowiak O, Mancioppi V, Passanisi S Children (Basel). 2024; 11(8).

PMID: 39201842 PMC: 11352692. DOI: 10.3390/children11080907.

References
1.
Shah V, DuBose S, Li Z, Beck R, Peters A, Weinstock R . Continuous Glucose Monitoring Profiles in Healthy Nondiabetic Participants: A Multicenter Prospective Study. J Clin Endocrinol Metab. 2019; 104(10):4356-4364. PMC: 7296129. DOI: 10.1210/jc.2018-02763. View

2.
Matabuena M, Pazos-Couselo M, Alonso-Sampedro M, Fernandez-Merino C, Gonzalez-Quintela A, Gude F . Reproducibility of continuous glucose monitoring results under real-life conditions in an adult population: a functional data analysis. Sci Rep. 2023; 13(1):13987. PMC: 10460390. DOI: 10.1038/s41598-023-40949-1. View

3.
Sofizadeh S, Pehrsson A, Olafsdottir A, Lind M . Evaluation of Reference Metrics for Continuous Glucose Monitoring in Persons Without Diabetes and Prediabetes. J Diabetes Sci Technol. 2020; 16(2):373-382. PMC: 8861786. DOI: 10.1177/1932296820965599. View

4.
Bailey K, Little J, Jung M . Self-Monitoring Using Continuous Glucose Monitors with Real-Time Feedback Improves Exercise Adherence in Individuals with Impaired Blood Glucose: A Pilot Study. Diabetes Technol Ther. 2016; 18(3):185-93. DOI: 10.1089/dia.2015.0285. View

5.
Klonoff D, Nguyen K, Xu N, Gutierrez A, Espinoza J, Vidmar A . Use of Continuous Glucose Monitors by People Without Diabetes: An Idea Whose Time Has Come?. J Diabetes Sci Technol. 2022; 17(6):1686-1697. PMC: 10658694. DOI: 10.1177/19322968221110830. View