» Articles » PMID: 38600834

Ion Parking in Native Mass Spectrometry

Overview
Journal Analyst
Specialty Chemistry
Date 2024 Apr 11
PMID 38600834
Authors
Affiliations
Soon will be listed here.
Abstract

A forced, damped harmonic oscillator model for gas-phase ion parking using single-frequency resonance excitation is described and applied to high-mass ions of relevance to native mass spectrometry. Experimental data are provided to illustrate key findings revealed by the modelling. These include: (i) ion secular frequency spacings between adjacent charge states of a given protein are essentially constant and decrease with the mass of the protein (ii) the mechanism for ion parking of high mass ions is the separation of the ion clouds of the oppositely-charged ions with much less influence from an increase in the relative ion velocity due to resonance excitation, (iii) the size of the parked ion cloud ultimately limits ion parking at high / ratio, and (iv) the extent of ion parking of off-target ions is highly sensitive to the bath gas pressure in the ion trap. The model is applied to ions of 17 kDa, 467 kDa, and 2 MDa while experimental data are also provided for ions of horse skeletal muscle myoglobin (≈17 kDa) and β-galactosidase (≈467 kDa). The model predicts and data show that it is possible to effect ion parking on a 17 kDa protein to the 1 charge state under trapping conditions that are readily accessible with commercially available ion traps. It is also possible to park β-galactosidase efficiently to a roughly equivalent / ratio (, the 26 charge state) under the same trapping conditions. However, as charge states decrease, analyte ion cloud sizes become too large to allow for efficient ion trapping. The model allows for a semi-quantitative prediction of ion trapping performance as a function of ion trapping, resonance excitation, and pressure conditions.

Citing Articles

Accessing Different Protein Conformer Ensembles with Tunable Capillary Vibrating Sharp-Edge Spray Ionization.

Sharif D, Dewasurendra V, Sultana M, Mahmud S, Banerjee C, Rahman M J Phys Chem B. 2025; 129(5):1626-1639.

PMID: 39878076 PMC: 11808649. DOI: 10.1021/acs.jpcb.4c04842.


Single-Frequency Ion Parking in a Digital 3D Quadrupole Ion Trap.

Fu L, Eakins G, Carlsen M, McLuckey S Int J Mass Spectrom. 2024; 503.

PMID: 39006163 PMC: 11238766. DOI: 10.1016/j.ijms.2024.117282.

References
1.
De Bruycker K, Welle A, Hirth S, Blanksby S, Barner-Kowollik C . Mass spectrometry as a tool to advance polymer science. Nat Rev Chem. 2023; 4(5):257-268. DOI: 10.1038/s41570-020-0168-1. View

2.
Makarov . Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis. Anal Chem. 2000; 72(6):1156-62. DOI: 10.1021/ac991131p. View

3.
Hernandez H, Robinson C . Determining the stoichiometry and interactions of macromolecular assemblies from mass spectrometry. Nat Protoc. 2007; 2(3):715-26. DOI: 10.1038/nprot.2007.73. View

4.
Hopper J, Sokratous K, Oldham N . Charge state and adduct reduction in electrospray ionization-mass spectrometry using solvent vapor exposure. Anal Biochem. 2011; 421(2):788-90. DOI: 10.1016/j.ab.2011.10.034. View

5.
Rostom A, Fucini P, Benjamin D, Juenemann R, Nierhaus K, Hartl F . Detection and selective dissociation of intact ribosomes in a mass spectrometer. Proc Natl Acad Sci U S A. 2000; 97(10):5185-90. PMC: 25803. DOI: 10.1073/pnas.97.10.5185. View