» Articles » PMID: 38578023

Introducing a New Proforma for the Safe Use of Intraoperative Tourniquets in Orthopaedic Surgery

Overview
Specialty General Surgery
Date 2024 Apr 5
PMID 38578023
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: The routine use of pneumatic tourniquets in orthopaedic surgery is widely adopted in current practice; however, practice varies considerably based mainly on anecdotal and cultural traditions. This Quality Improvement Project evaluated current service as per the newly published British Orthopaedic Association Standards for Trauma & Orthopaedics guideline on 'The Safe Use of Intraoperative Tourniquets'.

Methods: Patient records were reviewed retrospectively for all patients who underwent orthopaedic surgery in September 2021 at one NHS hospital trust. Simultaneously, a nine-question survey was distributed to the orthopaedic teams allowing assessment of non-quantifiable aspects of the guidelines. The results were delivered as a local presentation, and trust-wide dissemination of posters using the mnemonic 'PRESSURE' was used to educate staff. The quantitative audit was repeated twice, after this intervention (March 2022) and after the advent of a new electronic patient record system with an online proforma (January 2023).

Results: There was significant improvement (<0.05) in all aspects of tourniquet documentation between the audit cycles. Maximum advised tourniquet duration was exceeded in <2% of cases regardless of guideline publication. Recommended pressures were used in less than one-third of cases in all audit cycles, with no significant change throughout. More than 50% of respondents sized their tourniquet on 'whatever looked best fit'.

Conclusions: Despite tourniquet usage being part of the UK Trauma & Orthopaedic Surgery curriculum, this study is the first to highlight a lack of compliance with 'gold standard' guidelines and the need for increased training for staff to ensure patients are exposed to the safest possible environment. Although electronic proformas can aid recording of information, the limitation to change is cultural tradition and anecdotal experience.

Citing Articles

Embracing Digital Transformation: A Three-Cycle Audit on Improving Intraoperative Tourniquet Documentation Following BOAST (British Orthopaedic Association Standards for Trauma) Guidelines.

Kafagi A, Tahoun M, Pillai A Cureus. 2024; 16(7):e65652.

PMID: 39205710 PMC: 11352021. DOI: 10.7759/cureus.65652.

References
1.
Klenerman L . The tourniquet in surgery. J Bone Joint Surg Br. 1962; 44-B:937-43. DOI: 10.1302/0301-620X.44B4.937. View

2.
WARREN P, Hardiman P, Woolf V . Limb exsanguination. I. The arm: effect of angle of elevation and arterial compression. Ann R Coll Surg Engl. 1992; 74(5):320-2. PMC: 2497672. View

3.
. Recommended practices for the use of the pneumatic tourniquet in the perioperative practice setting. AORN J. 2008; 86(4):640-655. DOI: 10.1016/j.aorn.2007.09.004. View

4.
Ahmed I, Chawla A, Underwood M, Price A, Metcalfe A, Hutchinson C . Time to reconsider the routine use of tourniquets in total knee arthroplasty surgery. Bone Joint J. 2021; 103-B(5):830-839. PMC: 8091001. DOI: 10.1302/0301-620X.103B.BJJ-2020-1926.R1. View

5.
Sadri A, Braithwaite I, Abdul-Jabar H, Sarraf K . Understanding of intra-operative tourniquets amongst orthopaedic surgeons and theatre staff--a questionnaire study. Ann R Coll Surg Engl. 2010; 92(3):243-5. PMC: 3080086. DOI: 10.1308/003588410X1251883644060. View