» Articles » PMID: 38537029

Influence of Repositioning Guides' Color and Usage on Precision in Tooth Color Measurement with a Clinical Spectrophotometer

Overview
Journal J Appl Oral Sci
Specialty Dentistry
Date 2024 Mar 27
PMID 38537029
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Repositioning guides are commonly employed in clinical studies to ensure consistent tooth color measurements. Yet, their influence on measured color remains uncertain.

Objective: This study evaluated the impact of repositioning guides' color and usage on tooth color measurement using a clinical spectrophotometer.

Methodology: In total, 18 volunteers participated in this study, in which the color of their upper left central incisor and upper left canine was measured with or without repositioning guides (control). The guides were made from pink, blue, or translucent silicone, as well as an acetate-based bleaching tray. Tooth color was measured in triplicates using a clinical spectrophotometer based on the CIELAB system. The standard deviations of these readings were used to estimate reproducibility, and color differences (ΔE00) between the measurements with guides and the control were calculated.

Results: Repositioning guides had a minimal effect on L* values and no effect on b* values. The use of pink silicone increased a* values, whereas blue or translucent silicone reduced them. Irrespective of the evaluated tooth, the lowest ΔE00 values were observed for the translucent silicone and bleaching tray. The usage of guides only affected data variability for the L* color coordinate.

Conclusion: Using repositioning guides can significantly impact the precision of tooth color measurement with a clinical spectrophotometer.

Citing Articles

The Effect of Positioning Guide Color on Shade Measurements Using a Clinical Spectrophotometer.

Dumke J, Fantine L, Nogueira S, Gaidarji B, Righes D, Mariano da Rocha B Braz Dent J. 2024; 35:e245995.

PMID: 39476050 PMC: 11520490. DOI: 10.1590/0103-6440202405995.

References
1.
Fernandez Millan D, Gallas Torreira M, Alonso DE LA Pena V . Using a repositioning splint to determine reproducibility in the color registers of a dental spectrophotometer. J Esthet Restor Dent. 2019; 32(1):19-25. DOI: 10.1111/jerd.12532. View

2.
Tabatabaian F, Beyabanaki E, Alirezaei P, Epakchi S . Visual and digital tooth shade selection methods, related effective factors and conditions, and their accuracy and precision: A literature review. J Esthet Restor Dent. 2021; 33(8):1084-1104. DOI: 10.1111/jerd.12816. View

3.
Vochikovski L, Rezende M, Maran B, de Paula J, Machado L, Kossatz S . Combined Bleaching Technique Versus At-home Bleaching-A Single-blind Randomized Controlled Trial. Oper Dent. 2022; 47(3):247-257. DOI: 10.2341/20-283-C. View

4.
Melgosa M, Ruiz-Lopez J, Li C, Garcia P, Della Bona A, Perez M . Color inconstancy of natural teeth measured under white light-emitting diode illuminants. Dent Mater. 2020; 36(12):1680-1690. DOI: 10.1016/j.dental.2020.10.001. View

5.
Paravina R, Majkic G, Imai F, Powers J . Optimization of tooth color and shade guide design. J Prosthodont. 2007; 16(4):269-76. DOI: 10.1111/j.1532-849X.2007.00189.x. View