» Articles » PMID: 38496810

A 24-month Randomized Clinical Study of Flowable Bulk-fill Resin Composites in Class III Restorations

Overview
Journal J Clin Exp Dent
Specialty Dentistry
Date 2024 Mar 18
PMID 38496810
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The 24-month clinical performance of 3 commercially available flowable bulk-fill resin composites in Class III restorations was evaluated.

Material And Methods: Forty-two patients, 27 females (64.3%) and 15 (35.7%) males, received at least 3 Class III restorations that never exceeded 4 mm depth and width. One hundred thirty-eight teeth, divided up into three groups (n=46), were randomly restored with Admira Fusion x-base (AFB), Estelite Bulk Fill Flow (EBF) and SDR flow+ (SDR) in one single increment. A 2-step self-etch adhesive system Clearfil SE Bond (C-SE) with selective enamel etching was used for all restorations. The restorations were clinically evaluated using a slightly modified USPHS criteria at the baseline and every 6 months for 24 months. Success rates of each material between the baseline and at 24 months were compared with the McNemar test. At each timepoint, the comparison of the clinical performance among materials in terms of the ratings of the considered criteria was analyzed by using the Friedman and Cochran's Q tests.

Results: At the end of the 24-month follow-up, the overall clinical success rate was 100% for each tested material. However, significant differences among the composites were highlighted for several criteria involving the marginal adaptation, marginal discoloration, surface texture, surface staining and color match.

Conclusions: The flowable bulk-fill resin composites tested showed an overall good effectiveness for Class III restorations after the 24 months, although significant rating differences among the materials emerged for some specific clinical criteria. Bulk-fill, Class III restoration, flowable composite, clinical study, self-etching adhesive.

Citing Articles

Color Stability of Bulk-Fill Flowable Resin Composites After Artificial Aging.

Floriani F, Jurado C, Madhu N, Lackey M, Azpiazu-Flores F, Lopes G Dent J (Basel). 2024; 12(11).

PMID: 39590400 PMC: 11592736. DOI: 10.3390/dj12110350.


Kinetic of Light Transmission during Setting and Aging of Modern Flowable Bulk-Fill Composites.

Ilie N, Hogg C Materials (Basel). 2024; 17(17).

PMID: 39274681 PMC: 11396306. DOI: 10.3390/ma17174292.

References
1.
Van Meerbeek B, Yoshihara K, Yoshida Y, Mine A, De Munck J, Van Landuyt K . State of the art of self-etch adhesives. Dent Mater. 2010; 27(1):17-28. DOI: 10.1016/j.dental.2010.10.023. View

2.
Akpata E, Behbehani J . Effect of bonding systems on post-operative sensitivity from posterior composites. Am J Dent. 2006; 19(3):151-4. View

3.
Reusens B, DHoore W, Vreven J . In vivo comparison of a microfilled and a hybrid minifilled composite resin in Class III restorations: 2-year follow-up. Clin Oral Investig. 2000; 3(2):62-9. DOI: 10.1007/s007840050080. View

4.
Hirata R, Clozza E, Giannini M, Farrokhmanesh E, Janal M, Tovar N . Shrinkage assessment of low shrinkage composites using micro-computed tomography. J Biomed Mater Res B Appl Biomater. 2014; 103(4):798-806. DOI: 10.1002/jbm.b.33258. View

5.
Ilie N, Hickel R . Investigations on a methacrylate-based flowable composite based on the SDR™ technology. Dent Mater. 2011; 27(4):348-55. DOI: 10.1016/j.dental.2010.11.014. View