» Articles » PMID: 38469259

Validity of Clinical Diagnostic Criteria for Sleep Bruxism by Comparison with a Reference Standard Using Masseteric Electromyogram Obtained with an Ultraminiature Electromyographic Device

Overview
Date 2024 Mar 12
PMID 38469259
Authors
Affiliations
Soon will be listed here.
Abstract

Evaluation of sleep bruxism (SB) in clinical practice is currently conducted based on clinical findings, i.e., clinical diagnostic criteria consisting of medical interview, findings of tooth wear, and symptoms of temporomandibular joint (TMJ) and muscles. However, there are many unclear points about validity of the criteria. In this study, validity tests were conducted to clarify the accuracy of the clinical diagnostic criteria for SB by comparison with a reference standard using a single-channel masseteric electromyogram (EMG) obtained with ultraminiature electromyographic devices. The subjects included 30 'probable' bruxers (P-bruxers) who were clinically diagnosed as having SB and 30 non-bruxers. EMG was recorded during sleep under unrestrained and accustomed condition at each subject's home using ultraminiature cordless EMG devices. Bursts with amplitudes of more than 5%, 10%, 20% of the maximum voluntary contraction (MVC) value (EMG-burst-5%, EMG-burst-10%, and EMG-burst-20%) and episodes of sleep bruxism (EMG-episode) were selected for analyses. In all conditions for burst selection, the P-bruxer group showed a significantly larger number of bursts and episodes than those in the non-bruxer group. Accuracy of the clinical diagnosis criteria was 66.7% with the reference standard using EMG-burst-5%/h and 58.3% with that using EMG-episodes/h. By applying single-channel EMG as the reference standard, we were able to conduct validity tests of clinical diagnostic criteria with a larger sample. It was clarified that the level of accuracy of clinical diagnostic criteria for SB were not high despite using the combination of an interview and clinical findings.

Citing Articles

Prevalence and Severity of Sleep Bruxism in Edentulous Patients: A Cross-Sectional Study.

Luchi Kloppel N, Pauletto P, Meiriely de Almeida Lopes N, Floriani F, Lidani R, De Luca Canto G Int J Dent. 2024; 2024:7498654.

PMID: 39553306 PMC: 11567726. DOI: 10.1155/2024/7498654.

References
1.
Stuginski-Barbosa J, Porporatti A, Costa Y, Svensson P, Conti P . Agreement of the International Classification of Sleep Disorders Criteria with polysomnography for sleep bruxism diagnosis: A preliminary study. J Prosthet Dent. 2016; 117(1):61-66. DOI: 10.1016/j.prosdent.2016.01.035. View

2.
Yamaguchi T, Abe S, Rompre P, Manzini C, Lavigne G . Comparison of ambulatory and polysomnographic recording of jaw muscle activity during sleep in normal subjects. J Oral Rehabil. 2011; 39(1):2-10. DOI: 10.1111/j.1365-2842.2011.02232.x. View

3.
Lobbezoo F, Ahlberg J, Glaros A, Kato T, Koyano K, Lavigne G . Bruxism defined and graded: an international consensus. J Oral Rehabil. 2012; 40(1):2-4. DOI: 10.1111/joor.12011. View

4.
Jonsgar C, Hordvik P, Berge M, Johansson A, Svensson P, Johansson A . Sleep bruxism in individuals with and without attrition-type tooth wear: An exploratory matched case-control electromyographic study. J Dent. 2015; 43(12):1504-10. DOI: 10.1016/j.jdent.2015.10.002. View

5.
Manfredini D, Ahlberg J, Castroflorio T, Poggio C, Guarda-Nardini L, Lobbezoo F . Diagnostic accuracy of portable instrumental devices to measure sleep bruxism: a systematic literature review of polysomnographic studies. J Oral Rehabil. 2014; 41(11):836-42. DOI: 10.1111/joor.12207. View