» Articles » PMID: 38445511

Impact of Cardiac Size on Diagnostic Performance of Single-photon Emission Computed Tomography Myocardial Perfusion Imaging: Insights from the REgistry of Fast Myocardial Perfusion Imaging with NExt Generation Single-photon Emission Computed...

Abstract

Aims: Variation in diagnostic performance of single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) has been observed, yet the impact of cardiac size has not been well characterized. We assessed whether low left ventricular volume influences SPECT MPI's ability to detect obstructive coronary artery disease (CAD) and its interaction with age and sex.

Methods And Results: A total of 2066 patients without known CAD (67% male, 64.7 ± 11.2 years) across nine institutions underwent SPECT MPI with solid-state scanners followed by coronary angiography as part of the REgistry of Fast Myocardial Perfusion Imaging with NExt Generation SPECT. Area under receiver-operating characteristic curve (AUC) analyses evaluated the performance of quantitative and visual assessments according to cardiac size [end-diastolic volume (EDV); <20th vs. ≥20th population or sex-specific percentiles], age (<75 vs. ≥75 years), and sex. Significantly decreased performance was observed in patients with low EDV compared with those without (AUC: population 0.72 vs. 0.78, P = 0.03; sex-specific 0.72 vs. 0.79, P = 0.01) and elderly patients compared with younger patients (AUC 0.72 vs. 0.78, P = 0.03), whereas males and females demonstrated similar AUC (0.77 vs. 0.76, P = 0.67). The reduction in accuracy attributed to lower volumes was primarily observed in males (sex-specific threshold: EDV 0.69 vs. 0.79, P = 0.01). Accordingly, a significant decrease in AUC, sensitivity, specificity, and negative predictive value for quantitative and visual assessments was noted in patients with at least two characteristics of low EDV, elderly age, or male sex.

Conclusion: Detection of CAD with SPECT MPI is negatively impacted by small cardiac size, most notably in elderly and male patients.

Citing Articles

Exosomal miRNA-21-5p and miRNA-21-3p as key biomarkers of myocardial infarction.

Sahebi R, Gandomi F, Shojaei M, Farrokhi E Health Sci Rep. 2024; 7(7):e2228.

PMID: 38983683 PMC: 11232052. DOI: 10.1002/hsr2.2228.

References
1.
Nudi F, Iskandrian A, Schillaci O, Peruzzi M, Frati G, Biondi-Zoccai G . Diagnostic Accuracy of Myocardial Perfusion Imaging With CZT Technology: Systemic Review and Meta-Analysis of Comparison With Invasive Coronary Angiography. JACC Cardiovasc Imaging. 2017; 10(7):787-794. DOI: 10.1016/j.jcmg.2016.10.023. View

2.
Einstein A, Pascual T, Mercuri M, Karthikeyan G, Vitola J, Mahmarian J . Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS). Eur Heart J. 2015; 36(26):1689-96. PMC: 4493324. DOI: 10.1093/eurheartj/ehv117. View

3.
Singh V, Pencina M, Einstein A, Liang J, Berman D, Slomka P . Impact of train/test sample regimen on performance estimate stability of machine learning in cardiovascular imaging. Sci Rep. 2021; 11(1):14490. PMC: 8280147. DOI: 10.1038/s41598-021-93651-5. View

4.
Jaarsma C, Leiner T, Bekkers S, Crijns H, Wildberger J, Nagel E . Diagnostic performance of noninvasive myocardial perfusion imaging using single-photon emission computed tomography, cardiac magnetic resonance, and positron emission tomography imaging for the detection of obstructive coronary artery disease: a.... J Am Coll Cardiol. 2012; 59(19):1719-28. DOI: 10.1016/j.jacc.2011.12.040. View

5.
Iskandar A, Limone B, Parker M, Perugini A, Kim H, Jones C . Gender differences in the diagnostic accuracy of SPECT myocardial perfusion imaging: a bivariate meta-analysis. J Nucl Cardiol. 2012; 20(1):53-63. DOI: 10.1007/s12350-012-9646-2. View